For non-Malaysian customers are required to make purchase from NEX Instrument Inc website at
Mitsubishi Electric
Sort by
Show result
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : FR-E720-3.7K
  • Manufacturer : Mitsubishi Electric
RM1,789.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : FR-E720-15K
  • Manufacturer : Mitsubishi Electric
RM6,316.00
  • Even though we have this part in stock, it may take several days for internal process to complete. Goods will be delivered within 5 working days.
  • Input: 16 points, 100 to 120 VAC, 10 mA, response time: 35 ms, 16 points/common
  • Output: 12 points, 24 VDC/240 VAC, 2 A/point, 5 A/common, response time: 12 ms, 8 points/common, 3 points/common
  • Independent contact, 36-point terminal block
  • Refurbished with 1 year warranty, original packing
  • Shipping Weight: 1.5 kg
RM1,265.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : FR-D720-0.1K
  • Manufacturer : Mitsubishi Electric
RM956.80
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : FR-E720-0.2K
  • Manufacturer : Mitsubishi Electric
RM1,016.60
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : FR-E740-0.4K, 415V
  • Manufacturer : Mitsubishi Electric
RM2,539.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : 329A3529P001
  • Manufacturer : Metrix
RM5,828.20
  • Condition : Brand New

  • Warranty : 1 Year

  • Part Number : 3M 10336

  • Manufacturer : Mitsubishi Electric

RM120.00
  • Even though we have this part in stock, it may take several days for internal process to complete. Goods will be delivered within 5 working days.
  • Input: 16 points, 12/24 VDC, 3/7 mA, response time: 10 ms, 16 points/common
  • Output: 12 points,24 VDC/240 VAC, 2 A/point, 5 A/common, response time: 12 ms, 8 points/common, 3 points/common
  • Independent contact, 36-point terminal block
  • Refurbished with 1 year warranty, original packing
  • Shipping Weight: 1.5 kg
RM1,048.80
  • Even though we have this part in stock, it may take several days for internal process to complete. Goods will be delivered within 5 working days.
  • Input: 32 points, 12/24 VDC, 3/7 mA, Response Time: 10ms, 16 points/common, positive common
  • Output: 24 points, 24 VDC/240 VAC, 2 A/point, 5 A/common, response time: 12 ms, 8 points/common
  • 36-point terminal block
  • Refurbished with 1 year warranty, original packing
  • Shipping Weight: 2.0 Kg
RM1,191.40
  • Even though we have this part in stock, it may take several days for internal process to complete. Goods will be delivered within 5 working days.
  • Input: 32 points, 12/24 VDC, 3/7 mA, response time: 10 ms, 16 points/common, positive common
  • Output: 24 points, 12/24 VDC, leakage at OFF:0.1 mA, response time: 2 ms, 8 points/common
  • With surge suppressor, 36-point terminal block
  • Refurbished with 1 year warranty, original packing
  • Shipping Weight: 1.6 kg
RM1,265.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1S62DA
  • Manufacturer : Mitsubishi Electric
RM823.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1S68AD
  • Manufacturer : Mitsubishi Electric
RM782.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SD61
  • Manufacturer : Mitsubishi Electric
RM566.00
  • Even though we have this part in stock, it may take several days for internal process to complete. Goods will be delivered within 5 working days.
  • BLANK COVER
  • REFURBISHED WITH 1 YEAR WARRANTY, ORIGINAL PACKING
  • SHIPPING WEIGHT: 1 kg
RM78.20
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SJ71QC24
  • Manufacturer : Mitsubishi Electric
RM827.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SJHCPU
  • Manufacturer : Mitsubishi Electric
RM1,164.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SX41
  • Manufacturer : Mitsubishi Electric
RM276.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SX80
  • Manufacturer : Mitsubishi Electric
RM377.20
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SX81
  • Manufacturer : Mitsubishi Electric
RM634.80
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SY41
  • Manufacturer : Mitsubishi Electric
RM276.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SY80
  • Manufacturer : Mitsubishi Electric
RM680.80
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SY81
  • Manufacturer : Mitsubishi Electric
RM524.40
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number :A616AD
  • Manufacturer :Mitsubishi Electric
RM1,704.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number :A6BAT
  • Manufacturer :Mitsubishi Electric
RM29.00
  • Estimated Delivery Time: 1 Week
  • 37-pin D-sub connector
  • Soldering type
  • Shipping Weight: 1 kg
RM87.40
  • Estimated Lead Time : 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Product No. : A6TBX36E

  • Product type : Terminal Block Converter Module

  • For negative common type input modules (standard type)

  • Applicable wire size : 0.75 to 2mm

  • Shipping Weight : 1.5 Kg

RM230.00
  • Estimated Lead Time : 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Product No. : AC30TB-E

  • Product type : Terminal Block Cable

  • Shipping Weight : 1.5 Kg

RM276.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : AJ65SBT-62DA
  • Manufacturer : Mitsubishi Electric
RM878.08
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : AJ65SBT-64AD
  • Manufacturer : Mitsubishi Electric
RM865.00
  • Estimated Lead Time : 7 - 10 working days.

  • Manufacturer : Mitsubishi Electric

  • Product No. : AJ65SBTB1-16DT1

  • Product type : Input/Output Combined Module

  • 8 input points DC24V(5mA) 1-wire type response time 0.2ms 

  • 8 output points DC24V(0.5A) 1-wire type transistor output terminal block type

  • Common wiring method 16 points/1 common (Terminal block single wire type) 

  • Number of stations occupied 1 station 32 points assignment (use 16 points)

  • Shipping weight : 5 Kg

RM607.20
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : AJ65SBTB1-32D1
  • Manufacturer : Mitsubishi Electric
RM902.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : AJ65SBTB1-32DT3
  • Manufacturer : Mitsubishi Electric
RM699.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days

  • Manufacturer : Mitsubishi Electric

  • Number of output points : 8 points

  • Isolation method : Photocoupler

  • Rated load voltage : 100 to 240 V AC 50/60 Hz±5 %

  • Load voltage distortion rate : Within 5 %

  • Max. load voltage : 264 V AC

  • Max. load current : 0.6 A/point 2.4 A/common

  • Min. load voltage/current : 50 V AC 100 mA, 100 V AC 10 mA, 240

  • Shipping Weight : 2.5 Kg

RM989.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65VBTCU-68ADVN

  • CC-Link analog-to-digital conversion unit AJ65VBTCU-68ADVN

  • Number of analog input points : 8 points (8 channels)

  • Analog input Voltage : DC-10 to + 10 V (input resistance value: 1 MΩ)

  • Digital output : -4096 to + 4095

  • I / O characteristics, resolution Input range : Digital output value (maximum resolution)

  • Voltage input 0 to 5 V : 0 to 4000 (1.25 mV)

  • 1 to 5 V : 0 to 4000 (1.0 mV)

  • -10 to 10 V : -4000 to 4000 (2.5 mV)

  • User range setting 1 (-10 to 10 V) : -4000 to 4000 (2.5 mV)

  • User range setting 2 (0 to 5 V) : 0 to 4000 (1.0 mV)

  • Accuracy (accuracy with respect to the maximum value of the digital output value) Ambient temperature: 25 ± 5 ° C : ± 0.3%

  • Ambient temperature: 0 to 55 ° C : ± 0.2%

  • A / D conversion speed : 1 ms / channel

  • Absolute maximum input Voltage : ± 15 V

  • Insulation method : Communication system and analog input at one time: Photocoupler Isolated power supply system and analog input at one time: Transformer Isolation channel to non-insulation

  • Withstand voltage : Power supply . Communication system all together and analog input Bulk: AC 500 V 1 minute

  • Protection grade : IP 1 XB

  • Station type : Remote device station (Ver.1 remote device station or Ver.2 remote device station)

  • Number of occupied stations : Ver.1 Remote device station: 3 stations Ver.2 Remote device station: 1 station (extended cyclic setting: 4 times)

  • Unit power supply Voltage : DC 24 V (DC 20.4 to 26.4 V, ripple ratio within 5%)

  • Current : 0.10 A (24 VDC)

  • Inrush current : 4.2 A, 1.2 ms or less

  • External wiring connection method : One-touch connector for communication (sold separately) Unit power supply unit: Power supply . One touch connector for FG (sold separately) Input / output unit: One touch connector for I / O (sold separately)

  • communication cable : Ver.1.10 compatible CC-Link dedicated cable: FANC-110SBH, FA-CBL 200PSBH, CS-110

  • External dimensions Height (H) : 115 mm

  • Width (W) : 41 mm

  • Depth (D) : 67 mm

  • mass : 0.17 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.2 Kg

RM2,386.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65VBTCU-68DAVN

  • CC - Link Digital - Analog Conversion Unit AJ65VBTCU - 68DAVN

  • Number of analog output points : 8 points (8 channels)

  • Digital input : -4096 to + 4095

  • Analog output Voltage : DC-10 to + 10 V (external load resistance value: 2 kΩ to 1 MΩ)

  • I / O characteristics, resolution Output range : Digital input value (maximum resolution)

  • Voltage output 0 to 5 V : 0 to 4000 (1.25 mV)

  • 1 to 5 V : 0 to 4000 (1 mV)

  • -10 to 10 V : -4000 to 4000 (2.5 mV)

  • User range setting 1 (-10 to 10 V) : -4000 to 4000 (2.5 mV)

  • User range setting 2 (0 to 5 V) : 0 to 4000 (1 mV)

  • Accuracy (accuracy with respect to the maximum value of the analog output value) Ambient temperature: 25 ± 5 ° C : ± 0.2%

  • Ambient temperature: 0 to 55 ° C : ± 0.3%

  • D / A conversion speed : 1 ms / channel

  • Absolute maximum output Voltage : ± 12 V

  • Output short circuit protection : There

  • Insulation method : Communication system and analog output at one time: Photocoupler Isolated power supply system and analog output at one time: Transformer Isolation channel to non-insulation

  • Withstand voltage : Power supply . Communication system all together and analog output Batch: AC 500 V for 1 minute

  • Protection grade : IP 1 XB

  • Station type : Remote device station (Ver.1 remote device station or Ver.2 remote device station)

  • Number of occupied stations : Ver.1 Remote device station: 3 stations Ver.2 Remote device station: 1 station (extended cyclic setting: 4 times)

  • Unit power supply Voltage : DC 24 V (DC 20.4 to 26.4 V, ripple ratio within 5%)

  • Current : 0.15 A (at 24 VDC)

  • Inrush current : 4.3 A, 1.2 ms or less

  • External wiring connection method : One-touch connector for communication (sold separately) Unit power supply unit: Power supply . One touch connector for FG (sold separately) Input / output unit: One touch connector for I / O (sold separately)

  • communication cable : Ver.1.10 compatible CC-Link dedicated cable: FANC-110SBH, FA-CBL 200PSBH, CS-110

  • External dimensions Height (H) : 115 mm

  • Width (W) : 41 mm

  • Depth (D) : 67 mm

  • mass : 0.16 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.2 Kg

RM3,101.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • FX3U-3A-ADP

  • Analog input / output adapter FX3U - 3A - ADP

  • Analog input Analog input range Voltage input : DC 0 to 10 V (input resistance 198.7 kΩ)

  • Current input : DC 4 to 20 mA (input resistance 250 Ω)

  • Number of input channels : 2 channels

  • Absolute maximum input Voltage input : -0.5 V, +15 V

  • Current input : -2 mA, +30 mA

  • Input characteristics : Input mode (voltage / current input) can be set for each channel.

  • Digital output : 12 bit binary

  • resolution Voltage input : 2.5 mV (10 V x 1/4000)

  • Current input : 5 μA (16 mA X 1/3200)

  • Overall precision Voltage input : Ambient temperature 25 ° C ± 5 ° C ± 0.5% (± 50 mV) to full scale 10 V Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 100 mV) to full scale 10 V

  • Current input : Ambient temperature 25 ° C ± 5 ° C ± 0.5 % (± 80 μA) against full scale 16 mA Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 160 μA) for full scale 16 mA

  • A / D conversion time When FX3U / FX3UC sequencer is connected : 80 μs X Number of used input channels + 40 μs X Number of output output channels (data update every calculation cycle)

  • When FX3S / FX3G / FX3GC programmable controller is connected : 90 μs X number of used input channels + 50 μs X number of output output channels (data update every calculation cycle)

  • Insulation method : . Insulation between analog input / output section and sequencer by photo coupler . Insulation between drive power supply and analog input / output section by DC / DC converter . No isolation between each channel

  • Analog output Analog output range Voltage output : DC 0 to 10 V (external load resistance 5 k to 1 MΩ)

  • Current output : DC 4 to 20 mA (external load resistance 500 Ω or less)

  • Number of output channels : 1 channel

  • Output characteristics : Output mode (voltage / current output) can be set.

  • Digital input : 12 bit binary

  • resolution Voltage output : 2.5 mV (10 V x 1/4000)

  • Current output : 4 μA (16 mA X 1/4000)

  • Overall precision Voltage output : Ambient temperature 25 ° C ± 5 ° C ± 0.5% (± 50 mV) to full scale 10 V Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 100 mV) to full scale 10 V External load resistance (Rs) is less than 5 kΩ In addition, the following calculations increase. (It increases by 100 mV per 1%.) 47 X 100 / (Rs + 47) - 0.9 (%)

  • Current output : Ambient temperature 25 ° C ± 5 ° C ± 0.5 % (± 80 μA) against full scale 16 mA Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 160 μA) for full scale 16 mA

  • D / A conversion time When FX3U / FX3UC sequencer is connected : 80 μs X Number of used input channels + 40 μs X Number of output output channels (data update every calculation cycle)

  • When FX3S / FX3G / FX3GC programmable controller is connected : 90 μs X number of used input channels + 50 μs X number of output output channels (data update every calculation cycle)

  • Insulation method : . Insulation between analog input / output section and sequencer by photo coupler . Insulation between drive power supply and analog input / output section by DC / DC converter . No isolation between each channel

  • Number of occupied I / O points : 0 point (It does not relate to the maximum input / output point number of the sequencer)

  • Application sequencer : FX3S, FX3G (Ver.1.20 or later), FX3U (Ver.2.61 or later), FX3GC, FX3UC (Ver.2.61 or later) FX3S - CNV - ADP is required for connection to FX3S. For connection to FX 3 G, FX 3 G - CNV - ADP is required. To connect to FX3U and FX3UC - 32MT - LT (-2), a function expansion board is required.

  • mass : About 0.1 Kg

  • Power supply Conversion circuit drive power supply : DC24 V + 20% -15% 90 mA Connect a 24 VDC power supply to the terminal block and supply it.

  • Interface drive power supply : DC 5 V 20 mA Internal power is supplied from the DC 5 V power supply of the basic unit.

  • Ambient temperature : 0 to 55 ° C. ... Operating -25 to 75 ° C. ..... Save

  • Relative humidity : 5 to 95% RH (noncondensing).... in operation

  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)

  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)

  • Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse

  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si

  • tor with period of 30 to 100 Hz

  • Withstand voltage : Between all terminals and ground terminal: 500 VAC for 1 minute

  • Insulation resistance : Between all terminals and ground terminal: 500 MV DC 500 MΩ or more with an insulation resistance meter

  • ground : Class D grounding (grounding resistance: 100 Ω or less)Grounding should be dedicated ground or common ground.

  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

  • Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

  • Shipping Weight : 1.1 Kg

RM2,129.80
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • FX3U-4AD-PT-ADP

  • Analog input adapter for Pt 100 type temperature sensor FX 3 U - 4 AD - PT - ADP

  • Temperature sensor . temperature control input signal : Platinum resistance temperature detector 3 wire type Pt 100 JIS C 1604 - 1997

  • Number of input channels : 4 channels

  • Rated temperature range : -50 ° C to + 250 ° C (-58

RM1,614.60
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • FX1N-1DA-BD

  • Analog output board FX1N - 1DA - BD

  • Analog output Analog output range Voltage output : DC 0 V to 10 V (external load resistance 2 kΩ to 1 MΩ)

  • Current output : DC 4 mA to 20 mA (external load resistance 500 Ω or less)

  • Number of output channels : 1 channel

  • Output characteristics : Output characteristics can not be adjusted.

  • Digital input Voltage output : 12 bit binary

  • Current output : 11 bit binary

  • resolution Voltage output : 2.5 mV (10 V x 1/4000)

  • Current output : 8 μA (16 mA X 1/2000)

  • Overall precision Voltage output : ± 1% (± 0.1 V) for full scale 10 V

  • Current output : ± 1% (± 0.16 mA) for full scale 16 mA

  • D / A conversion time : Approximately 10 ms (D / A conversion started with the END instruction, output after approximately 10 ms)

  • Insulation method : No isolation between analog input and sequencer, between channels

  • Number of occupied I / O points : 0 point (It does not relate to the maximum input / output point number of the sequencer)

  • Application sequencer : FX 1 S (V 2.0 or later), FX 1 N (V 2.0 or later)

  • Power supply : Internal power supply from the sequencer

  • Ambient temperature : 0 to 55 ° C. ... Operating -20 to 70 ° C. ... Save

  • Relative humidity : 35 to 85% RH (noncondensing)...at operation

  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : Amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)

  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)

  • Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse

  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si

  • tor with period of 30 to 100 Hz

  • Withstand voltage : Non-insulated between analog output part and PLC main body (Do not perform withstand voltage test)

  • Insulation resistance : Non-insulated between the analog output part and the programmable controller (Do not conduct the insulation resistance test)

  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

  • Use altitude : It can not be used under an environment pressurized to 2,000 m or less under atmospheric pressure. It may break down.

  • Shipping Weight : 1.5 Kg

RM450.80
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days

  • Manufacturer : Mitsubishi Electric

  • Part number : A0J2CPU

  • Control method : Stored program, repetitive operation

  • I/O control method : Direct system

  • Programming language : Language dedicated to sequence control (combined use of relay symbol type, logic symbolic language and SAP language)

  • Sequence Instruction : 21 types

  • Basic instruction : 38 types

  • Application instruction : 21 types

  • Processing speed : Sequence instruction 4.4 to 5.6μs/step

  • Memory capacity : Max, 7k steps

  • Number of I/O points : 336 points (maximum 480 points when using extension base unit)

  • Self diagnostic function : Watch dog timer error monitor, battery error

  • AC down detection blown fuse detection, etc

  • Allowable instantaneous power failure period : Within 20ms

  • Weight : 0.75 kg

  • Shipping Weight : 2.8 Kg

RM1,343.20
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Q2MEM-16MBA

  • Q2MEM-16MBA

  • Memory type : ATA card

  • Memory capacity after formatting : 15982 KB

  • Number of storable files : 512 pieces

  • Number of insertion and removal : 5000 times

  • Number of writes : A million times

  • External dimensions Height (H) : 45 mm

  • Width (W) : 42.8 mm

  • Depth (D) : 3.3 mm

  • mass : 15 g

  • General specification : Refer to general specifications of CPU module.

  • Shipping Weight : 1 Kg

RM2,392.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Q2MEM-32MBA

  • ATA card Q2MEM-32MBA

  • Memory type : ATA card

  • Memory capacity after formatting : 31854 KB

  • Number of storable files : 512 pieces

  • Number of insertion and removal : 5000 times

  • Number of writes : A million times

  • External dimensions Height (H) : 45 mm

  • Width (W) : 42.8 mm

  • Depth (D) : 3.3 mm

  • mass : 15 g

  • General specification : Refer to general specifications of CPU module.

  • Shipping Weight : 1 Kg

RM4,788.60
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Q2MEM-8MBA

  • ATA card Q2MEM-8MBA

  • Memory type : ATA card

  • Memory capacity after formatting : 7982 KB

  • Number of storable files : 512 pieces

  • Number of insertion and removal : 5000 times

  • Number of writes : A million times

  • External dimensions Height (H) : 45 mm

  • Width (W) : 42.8 mm

  • Depth (D) : 3.3 mm

  • mass : 15 g

  • Shipping Weight : 1.1 Kg

  • Shipping Weight : 1 Kg

RM1,794.00
  • Estimated Lead Time : In stock. Usually ships in 3-5 working days.

  • Manufacturer : Mitsubishi Electric

  • Q00JCPU

  • Basic model QCPU Q00JCPU

  • control method : Stored program iteration operation

  • Input / output control method : Refresh method (Direct access input / output possible by specifying direct access input / output (DX, DY))

  • Programming language Sequence control language : Relay symbol word, logic symbolic word, MELSAP 3 (SFC), MELSAP-L, function block, structured text (ST)

  • processing speed Sequence instructions LD X 0 : 200 ns

  • MOV D 0 D 1 : 700 ns

  • Constant scan : 1 ~ 2000 ms (Can be set in 1 ms increments)

  • Program capacity : 8K steps (32K bytes)

  • Memory capacity Program memory (drive 0) : 58 KB

  • Standard ROM (Drive 4) : 58 KB

  • Maximum number of stored files Program memory : 6

  • Standard ROM : 6

  • Intelligent functional unit Parameter Maximum setting number Initial setting : 512 pieces

  • refresh : 256 pieces

  • Number of input / output devices : 2048 points (X / Y 0 to 7 FF)

  • Number of input / output points : 256 points (X / Y 0 to FF)

  • Number of device points Internal relay [M] : Default 8192 points (M0 to 8191) (changeable)

  • Latch relay [L] : Default 2048 points (L0 to 2047) (changeable)

  • Link relay [B] : Default 2048 points (B 0 - 7 FF) (changeable)

  • Timer [T] : Default 512 points (T0 to 511) (Shared with low-speed timer / high-speed timer) (Changeable) Low-speed timer / high- speed timer specified by instruction Low-speed timer / high-speed timer measurement unit is set by parameter (low-speed timer: 1 to 1000 ms, 1 ms increment, default 100 ms) (High-speed timer: 0.1 to 100.0 ms, 0.1 ms increments, default 10.0 ms)

  • Integration timer [ST] : Default 0 point (Shared with low speed integration timer / high speed integration timer) (Changeable) Low speed integration timer / high speed integration timer specified by instruction Set the measurement unit of low speed integration timer / high speed integration timer by parameter (low speed integration timer: 1000 ms, 1 ms increment, default 100 ms) (High-speed integration timer: 0.1 to 100.0 ms, 0.1 ms increments, default 10.0 ms)

  • Counter [C] : Normal counter: default 512 points (C 0 to 511) (changeable) Interrupt counter: maximum 128 points (default 0 point, set by parameter)

  • Data register [D] : Default 11136 points (D0 to 11135) (changeable)

  • Link register [W] : Default 2048 points (W 0 to 7 FF) (changeable)

  • Annunciator [F] : Default 1024 points (F0 to 1023) (changeable)

  • Edge relay [V] : Default 1024 points (V 0 to 1023) (changeable)

  • Link special relay [SB] : 1024 points (SB 0 to 3 FF) (Device number is fixed)

  • Link special register [SW] : 1024 points (SW 0 to 3 FF) (the number of device points is fixed)

  • Step relay [S] : 2048 points (S 0 ~ 127 / block) (Device number is fixed)

  • Index register [Z] : 10 points (Z 0 ~ 9) (Device number is fixed)

  • Pointer [P] : 300 points (P 0 ~ 299) (Device number is fixed)

  • Interrupt pointer [I] : 128 points (I 0 to 127) ( Number of device points is fixed) Periodic interval of system interrupt pointer I 28 to 31 can be set by parameter. (2 to 1000 ms, 1 ms increments) Default I 28: 100 ms, I 29: 40 ms, I 30: 20 ms, I 31 : 10 ms

  • Special relay [SM] : 1024 points (SM 0 ~ 1023) (Device number is fixed)

  • Special register [SD] : 1024 points (SD 0 ~ 1023) (Device number is fixed)

  • Function input [FX] : 16 points (FX 0 to F) (Device number is fixed)

  • Function output [FY] : 16 points (FY 0 to F) (the number of device points is fixed)

  • Function register [FD] : 5 points (FD 0 ~ 4) (Device number is fixed)

  • Link direct device : J□□ \ X□□, J□□ \ Y□□, J□□ \ SB□□, J□□ \ SB□□, J□□ \ SB□□, J□□ \ SW□□, J□□ \ SW□ Device specification form for directly accessing the link device of the network unit□

  • Intelligent functional unit device : Device specification that directly accesses buffer memory of intelligent function module Format: U□□ \ G□□

  • Latch (power outage hold) range : L 0 to 2047 (default 2048 points) [latch range can be set for B, F, V, T, ST, C, D, W]

  • RUN / PAUSE contact : One point of each RUN / PAUSE contact can be set from X 0 to 7 FF

  • Clock function : Year, month, day, hour, minute, second, day of the week (leap year automatic discrimination) accuracy: -3.20 ~ + 5.27s (. TYP + 1.98s) / d at 0 °C accuracy: -2.57 ~ + 5.27s (TYP + . 2.22 s) / d at 25 ° C. Accuracy: -11.68 to +3.65 s (TYP. -2.64 s) / d at 55 ° C.

  • Allowable momentary power failure time : Within 20 ms (AC 100 V or more)

  • DC 5 V Internal current consumption : 0.26 A

  • External dimensions Height (H) : 98 mm

  • Width (W) : 244.4 mm

  • Depth (D) : 98 mm

  • mass : 0.66 Kg

  • Power supply part :

  • Input supply voltage : AC 100 to 240 V (-15% to + 10%)

  • Input frequency : 50/60 Hz ± 5%

  • Input voltage distortion ratio : Within 5%

  • Input maximum apparent power : 105VA

  • Inrush current : 40 A within 8 ms

  • Rated output current DC 5V : 3A

  • Overcurrent protection DC 5V : 3.3 A or more

  • Overvoltage protection DC 5V : 5.5 to 6.5 V

  • efficiency : 65% or more

  • Withstand voltage : Input . LG collective and output . FG all at once AC 2300 V / 1 min (altitude 0 to 2000 m)

  • Insulation resistance : Input . LG collective and output . Between FG batch, input batch and LG, batch output and FG: 500 MV DC insulation resistance meter 10 MΩ or more

  • Operation indication : LED display (normal: green lighting, abnormal: off, CPU part "POWER" LED)

  • fuse : Built-in (user replaceable)

  • Contact output unit : None

  • External wiring connection method : Screw terminal block (M3.5 screw)

  • Base part :

  • Number of input / output units : Five

  • Applicable unit : MELSEC-Q series unit

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -25 to 75 ° C

  • Ambient operating humidity : 5 to 95% RH, non condensing

  • Storage ambient humidity : 5 to 95% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Device class : Class I

  • Shipping Weight : 1.7 Kg

RM1,706.60
  • ESTIMATED DELIVERY TIME: 7 Working Days
  • Manufacturer : Mitsubishi Electric
  • Product No. : Q00CPU
  • Number of I/O points: 1024 points
  • Number of I/O device points: 2048 points
  • Program capacity: 8 k steps
  • Basic instruction processing speed (LD instruction): 0.16
RM1,545.60
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Q80BD-J71GP21S-SX

  • CC-Link IE Controller Network Interface Board Q80BD-J71GP21S-SX

  • Maximum number of links per network LB : 32 K points (32768 points, 4 K bytes)

  • LW : 128K points (131072 points, 256 Kbytes)

  • LX : 8K points (8192 points, 1 Kbyte)

  • LY : 8K points (8192 points, 1 Kbyte)

  • Maximum link points per station LB : 16 K points (16384 points, 2 K bytes), extended mode: 32 K points (32768 points, 4 K bytes)

  • LW : 16 K points (16384 points, 2 K bytes), extended mode: 128 K points (131072 points, 256 K bytes)

  • LX : 8K points (8192 points, 1 Kbyte)

  • LY : 8K points (8192 points, 1 Kbyte)

  • Transient transmission capacity : Maximum 1920 bytes

  • communication speed : 1 Gbps

  • communication cable : Optical fiber cable that meets 1000 BASE-SX standards: multimode optical fiber (GI)

  • Applicable connector : Double LC type connector

  • Laser class (JIS C 6802, IEC 60825-1) : Class 1 laser products

  • Total extension distance : 66000 m (when 120 units are connected)

  • Maximum Inter-Station Distance : 550 m

  • Maximum number of connected stations : 120 units (management station: 1 unit, normal station: 119 units)

  • Maximum number of networks : 239

  • Maximum number of groups : 32

  • Communication method : Token ring method

  • Transmission path format : Double loop

  • External power supply Voltage : DC 20.4 to 31.2 V

  • Current : 0.27 A

  • Allowable momentary power failure time : 1 ms (level PS 1)

  • Number of installable sheets : Up to 4 sheets

  • Mounting slot : PCI slot or PCI-X slot (half size)

  • Number of occupied slots : 1

  • DC 5 V Internal current consumption : 1.10 A

  • mass : 0.14 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -25 to 75 ° C

  • Ambient operating humidity : 5 to 95% RH, non condensing

  • Storage ambient humidity : 5 to 95% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.2 Kg

RM12,452.20
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • QJ71GP21S-SX

  • CC-Link IE Controller Network Unit QJ71GP21S-SX

  • Maximum number of links per network LB : 32 K points (32768 points, 4 K bytes)

  • LW : 128K points (131072 points, 256 Kbytes)

  • LX : 8K points (8192 points, 1 Kbyte)

  • LY : 8K points (8192 points, 1 Kbyte)

  • Maximum link points per station LB : 16 K points (16384 points, 2 K bytes), extended mode: 32 K points (32768 points, 4 K bytes)

  • LW : 16 K points (16384 points, 2 K bytes), extended mode: 128 K points (131072 points, 256 K bytes)

  • LX : 8K points (8192 points, 1 Kbyte)

  • LY : 8K points (8192 points, 1 Kbyte)

  • Transient transmission capacity : Maximum 1920 bytes

  • communication speed : 1 Gbps

  • communication cable : Optical fiber cable that meets 1000 BASE-SX standards: multimode optical fiber (GI)

  • Applicable connector : Double LC type connector

  • Laser class (JIS C 6802, IEC 60825-1) : Class 1 laser products

  • Total extension distance : 66000 m (when 120 units are connected)

  • Maximum Inter-Station Distance : 550 m

  • Maximum number of connected stations : When the management station is the universal model QCPU: 120 (management station: 1 unit, normal station: 119 units) When the management station is a high performance model QCPU: 64 units (management station: 1 unit, normal station: 63 units)

  • Maximum number of networks : 239

  • Maximum number of groups : 32

  • Communication method : Token ring method

  • Transmission path format : Double loop

  • External power supply Voltage : DC 20.4 to 31.2 V

  • Current : 0.28 A

  • Allowable momentary power failure time : 1 ms (level PS 1)

  • Number of occupied I / O points : 48 points, 2 slots (I / O assignment: free 16 points + intelli 32 points)

  • DC 5 V Internal current consumption : 0.90 A

  • External dimensions Height (H) : 98 mm

  • Width (W) : 55.2 mm

  • Depth (D) : 90 mm

  • mass : 0.28 Kg

  • Shipping Weight : 1.3 Kg

RM8,795.20
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BT-64RD4

  • CC-Link platinum resistance temperature detector Pt 100 temperature input unit AJ65BT-64RD4

  • Number of channels : 4 channels

  • Digital output Temperature measurement value : 16-bit signed binary (-1800 to 6000: value to the first decimal place X 10 times) 32-bit signed binary (-180000 to 600000: value up to the third decimal place X 1000 times)

  • Measuring method : 4 wire type

  • Usable resistance temperature detector : Pt 100, JPt 100

  • Measurement temperature range Pt 100 : -180 to 600 ° C

  • JPt 100 : -180 to 600 ° C

  • Output current for temperature detection : 1 mA

  • resolution : 0.025 °C

  • Overall accuracy (accuracy with respect to maximum value) Ambient temperature: 25 ± 5 ° C : ± 0.1%

  • Ambient temperature: 20 ° C or less, 30 ° C or more : ± 0.25%

  • Conversion speed : 40 ms / channel

  • Insulation method : Between platinum resistance temperature detector input and CC-Link transmission system: Photocoupler isolation Channel to non-insulation

  • Withstand voltage : Between power supply system batch and earth, power supply system batch and communication system batch, communication system batch and temperature input batch, between temperature input batch and ground: AC 500 V for 1 minute

  • Insulation resistance : Between power supply system batch and earth, power supply system batch and communication system batch, between communication system batch and temperature input batch, between temperature input batch and ground: 500 MV with insulation resistance meter 10 MΩ or more

  • Station type : Remote device station (Ver.1 remote device station)

  • Number of occupied stations : 4 stations

  • Unit power supply Voltage : DC 24 V (DC 18 to 30 V)

  • Current : 0.17 A

  • Allowable momentary power failure time : 1 ms

  • External wiring connection method : Communication unit, Unit power supply unit: 7 points 2-piece terminal block (M3.5 screw) I / O section: 27 points 2 piece terminal block (M3.5 screw)

  • communication cable : CC-Link dedicated cable

  • External dimensions Height (H) : 65 mm

  • Width (W) : 151.9 mm

  • Depth (D) : 63 mm

  • mass : 0.38 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz , Amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, Amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.4 Kg

RM3,974.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BT-64RD3

  • CC-Link platinum resistance temperature detector Pt100 temperature input unit AJ65BT-64RD3

  • Number of channels : 4 channels

  • Digital output Temperature measurement value : 16-bit signed binary (-1800 to 6000: value to the first decimal place X 10 times) 32-bit signed binary (-180000 to 600000: value up to the third decimal place X 1000 times)

  • Measuring method : 3 wire type

  • Usable resistance temperature detector : Pt 100, JPt 100

  • Measurement temperature range Pt 100 : -180 to 600 ° C

  • JPt 100 : -180 to 600 ° C

  • Output current for temperature detection : 1 mA

  • resolution : 0.025 °C

  • Overall accuracy (accuracy with respect to maximum value) Ambient temperature: 25 ± 5 ° C : ± 0.1%

  • Ambient temperature: 20 ° C or less, 30 ° C or more : ± 0.25%

  • Conversion speed : 40 ms / channel

  • Insulation method : Between platinum resistance temperature detector input and CC-Link transmission system: Photocoupler isolation Channel to non-insulation

  • Withstand voltage : Between power supply system batch and earth, power supply system batch and communication system batch, communication system batch and temperature input batch, between temperature input batch and ground: AC 500 V for 1 minute

  • Insulation resistance : Between power supply system batch and earth, power supply system batch and communication system batch, between communication system batch and temperature input batch, between temperature input batch and ground: 500 MV with insulation resistance meter 10 MΩ or more

  • Station type : Remote device station (Ver.1 remote device station)

  • Number of occupied stations : 4 stations

  • Unit power supply Voltage : DC 24 V (DC 18 to 30 V)

  • Current : 0.17 A

  • Allowable momentary power failure time : 1 ms

  • External wiring connection method : Communication unit, Unit power supply unit: 7 points 2-piece terminal block (M3.5 screw) I / O section: 27 points 2 piece terminal block (M3.5 screw)

  • communication cable : CC-Link dedicated cable

  • External dimensions Height (H) : 65 mm

  • Width (W) : 151.9 mm

  • Depth (D) : 63 mm

  • mass : 0.38 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz , Amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, Amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.4 Kg

RM3,974.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BT-D75P2-S3

  • CC-Link Positioning Unit (Open Collector Output Type) AJ65BT-D75P2-S3

  • Number of control axes : 2 axes

  • Interpolation function : 2 axis linear interpolation 2 axis circular interpolation

  • control method : PTP (Point To Point) control trajectory control (both linear and arc configurable) Speed ??control Speed ??/ position switching control

  • Control unit : mm, inch, degree, pulse

  • Positioning data : 600 data / axis

  • backup : Parameter and positioning data can be saved in flash ROM (battery less)

  • Positioning Positioning method PTP control : Increment method / absolute method

  • Speed ??/ position switching control : Increment method / absolute method

  • Trajectory control : Increment method / absolute method

  • Positioning range Absolute method : Standard mode ? -214748364.8 to 214748364.7 μm ? -21474.83648 to 21474.83647 inch ? 0 to 359.99999 degree ? -2147483648 to 2147483647 pulse stepping motor mode ? -13421772.8 to 13421772.7 μm ? -1342.17728 to 1342.17727 inch ? 0 to 359.99999 degree ? -134217728 to 134217727 pulse

  • Increment method : Standard mode ? -214748364.8 to 214748364.7 μm ? -21474.83648 to 21474.83647 inch ? -21474.83648 to 21474.83647 degree ? -2147483648 to 2147483647 pulse stepping motor mode ? -13421772.8 to 13421772.7 μm ? -1342.17728 to 1342.17727 inch ? -1342.17728 to 1342.17727

RM3,653.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BTB2-16DR

  • CC-Link remote I / O unit (DC input / contact output, terminal block) AJ65BTB2-16DR

  • Input specification :

  • Input format : DC input (plus common / minus common common type)

  • Number of input points : 8 points

  • Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 28.8 V)

  • Rated input current : About 7 mA

  • Maximum number of simultaneous input points : 100%

  • ON voltage / ON current : 14 V or more / 3.5 mA or more

  • OFF voltage / OFF current : 6 V or less / 1.7 mA or less

  • Input resistance : About 3.3 kΩ

  • Input response time OFF → ON : 10 ms or less

  • ON → OFF : 10 ms or less

  • Input common type : 8 points / common (terminal trapezoid 2 wire type)

  • Input isolation method : Photocoupler isolation

  • Number of output points : 8 points

  • Rated switching voltage / current : DC 24 V 2A (resistance load) / 1 point, AC 240 V 2 A (cos φ = 1) / 1 point, 8 A / 1 common

  • Minimum opening / closing load : DC 5 V 1 mA

  • Maximum switching voltage : AC 250V DC 110V

  • lifespan mechanical : Over 20 million times

  • Electrical : Rated switching voltage . current load: 100,000 times or more AC 200 V 1.5 A, AC 240 V 1A (COS φ = 0.7): 100 thousand times or more AC 200 V 1A, AC 240 V 0.5 A (COS φ = 0.35): 100,000 times or more DC 24 V 1A, DC 100 V 0.1 A L / R = 7 ms): 100 thousand times or more

  • Maximum switching frequency : 3600 times / hour

  • Output response time OFF → ON : 10 ms or less

  • ON → OFF : 12 ms or less

  • Surge suppressor : None

  • Output section External power supply Voltage : DC 24 V ± 10% (ripple voltage 4 V pp or less)

  • Current : 45 mA or less (TYP. DC 24 V, all points ON)

  • Output common method : 8 points / common (terminal trapezoid 2 wire type)

  • Output isolation method : Photocoupler isolation

  • Withstand voltage : Between AC external terminal and ground: AC 1500 V 1 min DC external terminal Between ground and ground: AC 500 V 1 min

  • Insulation resistance : AC external terminal all together and ground, DC external terminal collective to ground: 500 MV DC insulation resistance meter 10 MΩ or more

  • Station type : Remote I / O station

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 24 V (ripple ratio within 5%) (allowable voltage range DC 15.6 to 28.8 V)

  • Current : 70 mA or less (TYP. At 24 VDC)

  • External wiring connection method : Communication part, Unit power supply part: 7 points 2 piece terminal block (M3.5 screw) I / O power supply part, input / output part: 37 points 2 piece terminal block (M3.5 screw)

  • External dimensions Height (H) : 65 mm

  • Width (W) : 197.4 mm

  • Depth (D) : 46 mm

  • mass : 0.43 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.4 Kg

RM1,508.80
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BTB1-16DT

  • CC-Link remote I / O unit (DC input / transistor output, terminal block) AJ65BTB1-16DT

  • Input specification :

  • Input format : DC input (plus common type)

  • Number of input points : 8 points

  • Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 28.8 V)

  • Rated input current : About 7 mA

  • Maximum number of simultaneous input points : 100%

  • ON voltage / ON current : 14 V or more / 3.5 mA or more

  • OFF voltage / OFF current : 6 V or less / 1.7 mA or less

  • Input resistance : About 3.3 kΩ

  • Input response time OFF → ON : 10 ms or less

  • ON → OFF : 10 ms or less

  • Input common type : 8 points / common (terminal trapezoid 1 wire type)

  • Input isolation method : Photocoupler isolation

  • Output format : Transistor output (sink type)

  • Number of output points : 8 points

  • Rated load voltage : DC12 / 24V (ripple ratio within 5%)

  • Used load voltage range : DC 10.2 to 28.8 V

  • Maximum load current : 0.5 A / 1 point, 4 A / 1 common

  • Maximum inrush current : 4 A 10 ms or less

  • Leakage current at OFF : 0.1 mA or less

  • Maximum voltage drop during ON : DC 0.9 V or less (TYP.) 0.5 A, DC 1.5 V or less (MAX.) 0.5 A

  • Output response time OFF → ON : 2 ms or less

  • ON → OFF : 2 ms or less (resistance load)

  • Surge suppressor : Zener diode

  • Output section External power supply Voltage : DC 12/24 V (ripple ratio within 5%) (allowable voltage range DC 10.2 to 28.8 V)

  • Current : 50 mA or less (TYP. DC 24 V, per common) External load current is not included

  • Output common method : 8 points / common (terminal trapezoid 1 wire type)

  • Output isolation method : Photocoupler isolation

  • Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

  • Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more

  • Station type : Remote I / O station

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 24 V (ripple ratio within 5%) (allowable voltage range DC 15.6 to 28.8 V)

  • Current : 70 mA or less (TYP. At 24 VDC)

  • External wiring connection method : Communication part, Unit power supply part: 7 points 2 piece terminal block (M3.5 screw) I / O power supply part, input / output part: 27 points 2 piece terminal block (M3.5 screw)

  • External dimensions Height (H) : 65 mm

  • Width (W) : 151.9 mm

  • Depth (D) : 46 mm

  • mass : 0.33 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.3 Kg

RM955.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BTB1-16D

  • CC-Link remote I / O unit (DC input, terminal block) AJ65BTB1-16D

  • Input format : DC input (plus common / minus common common type)

  • Number of input points : 16 points

  • Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 28.8 V)

  • Rated input current : About 7 mA

  • Maximum number of simultaneous input points : 100%

  • ON voltage / ON current : 14 V or more / 3.5 mA or more

  • OFF voltage / OFF current : 6 V or less / 1.7 mA or less

  • Input resistance : About 3.3 kΩ

  • Input response time OFF → ON : 10 ms or less

  • ON → OFF : 10 ms or less

  • Input common type : 16 points 1 common (terminal trapezoid 1 wire type)

  • Input isolation method : Photocoupler isolation

  • Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

  • Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more

  • Station type : Remote I / O station

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 24 V (ripple ratio within 5%) (allowable voltage range DC 15.6 to 28.8 V)

  • Current : 60 mA or less (TYP. At 24 VDC)

  • External wiring connection method : Communication part, Unit power supply part: 7 points 2 piece terminal block (M3.5 screw) I / O power supply part, input / output part: 27 points 2 piece terminal block (M3.5 screw)

  • External dimensions Height (H) : 65 mm

  • Width (W) : 151.9 mm

  • Depth (D) : 46 mm

  • mass : 0.32 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.3 Kg

RM955.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65SBT-RPT

  • CC-Link repeater (T branch) unit AJ65SBT-RPT

  • Transmission speed : 156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps (selectable)

  • Maximum number of connected stages : AJ65SBT-RPT only: Combination of 10-stage AJ65SBT-RPT and AJ65SBT-RPS: combination of 4-stage AJ65 SBT-RPT, AJ65 FBTA-RPH, AJ65 BTS-RPH, AJ 65 SBT RPG and AJ 65 BT-RPI: 3 steps

  • Maximum transmission distance of each segment : Different according to transmission speed

  • Maximum number of connected units : 64 units

  • Number of occupied stations : 0 (None)

  • Station number : No station number

  • Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

  • Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more

  • External wiring connection method : Communication unit, Unit power supply unit: 7 point 2-piece terminal block (M3.5 screw)

  • Unit power supply Voltage : DC 20.4 to 26.4 V

  • Current : 60.0 mA (TYP. At 24 VDC)

  • External dimensions Height (H) : 50 mm

  • Width (W) : 87.3 mm

  • Depth (D) : 40 mm

  • mass : 0.2 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.2 Kg

RM699.20