For non-Malaysian customers are required to make purchase from NEX Instrument Inc website at
Mitsubishi Electric
Sort by
Show result
  • Even though we have this part in stock, it may take several days for internal process to complete. Goods will be delivered within 5 working days.
  • Input: 16 points, 100 to 120 VAC, 10 mA, response time: 35 ms, 16 points/common
  • Output: 12 points, 24 VDC/240 VAC, 2 A/point, 5 A/common, response time: 12 ms, 8 points/common, 3 points/common
  • Independent contact, 36-point terminal block
  • Refurbished with 1 year warranty, original packing
  • Shipping Weight: 1.5 kg
RM1,265.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : FR-D720-0.1K
  • Manufacturer : Mitsubishi Electric
RM956.80
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : FR-E720-0.2K
  • Manufacturer : Mitsubishi Electric
RM1,016.60

 

  • Estimated Lead Time: 7-10 Working Days

  • Manufacturer: Mitsubishi Electric

  • FR-E740-0.4K, 415V

  • Easy and powerful compact inverter FREQROL-E700 series three-phase 400V FR-E740-0.4K

  • General-purpose three-phase 400V class Applicable motor capacity 0.4KW

  • Driving performance of small models top-level : implementation of 200% of the high torque during 0.5Hz the advanced magnetic flux vector control (3.7K or less). Short-time overload capability of the equipment the torque limiting function with to withstand up from the conventional model 200% 0.5 seconds to 200% for 3 seconds, became more tenaciously more powerful. 

  • By far the operability : equipped with M dial that further improve the operability of the scroll speed as a variable. The USB connector to achieve the setting support by the Wizard (interactive) function of standard equipment FR Configurator from the personal computer (setup software).

  •  
  •  Enhance scalability of : digital input by the installation of the built-in options, extension of the analog output, it can respond to various types of communication, including the CC-Link. Control terminal can be selected according to the application by the removable terminal block. It was realized the scalability of high-end comparable.

  • Product series :FREQROL-E700

  • type :Easy and powerful compact inverter FREQROL-E700 series three-phase 400V

  • Product No. :FR-E740-0.4K

  • Applicable motor capacity (kW) :0.4 kW

  • output :Rated capacity (kVA): 1.2

  • Rated current (A) :1.6

  • Overload current rating :150% 60s, 200% 3s (inverse time characteristics)

  • Voltage :3-phase 380 ~ 480V

  • Regenerative braking torque :Maximum value and the acceptable usage

  • -

  • Power supply :Voltage class

  • Three-phase 400V class

  • Rated input AC voltage and frequency :3-phase 380 ~ 480V 50Hz / 60Hz

  • AC voltage allowable variation :325 ~ 528V 50Hz / 60Hz

  • Frequency permissible variation :± 5%

  • Power supply capacity (kVA) :1.5

  • Protective structure (JEM 1030) :Closed form (IP20), all closed structure series will be IP40.

  • Cooling system :Self-cooling

  • Approximate Mass (kg) :1.4

  • Control specification :control method

  • Soft-PWM control / high carrier frequency PWM control (V / F control, advanced magnetic flux vector control, general-purpose magnetic flux vector control, optimum excitation control can be selected)

  • Output frequency range :0.2 ~ 400Hz

  • Frequency setting resolution :Analog input

  • 0.06Hz / 60Hz (terminal 2,4: 0 ~ 10V / 10bit), 0.12Hz / 60Hz (terminal 2,4: 0 ~ 5V / 9bit), 0.06Hz / 60Hz (terminal 4: 4 ~ 20mA / 10bit)

  • Digital input :0.01Hz

  • Frequency accuracy :Analog input

  • Within ± 0.5% of maximum output frequency (25°C ± 10°C)

  • Digital input :Within 0.01% of the set output frequency

  • Voltage / frequency characteristic :Base frequency 0 ~ 400Hz any setting possible, constant torque reduction torque pattern can be selected

  • Starting torque :200% more than if you set the (0.5Hz at the time) ... advanced magnetic flux vector control (3.7K or less)

  • Torque boost :Manual torque boost

  • Acceleration and deceleration time setting :0.01 ~ 360s, 0.1 ~ 3600s (acceleration and deceleration individually configurable), straight or S-shaped acceleration and deceleration mode can be selected

  • DC braking :Operating frequency (0 to 120 Hz), operation time (0 to 10s), the operating voltage (0-30%) Variable

  • Stall prevention operation level :Operating current level can be set (0 to 200% variable), presence or absence can be selected

  • Torque limit level :0-200%

  • Operation specification :Operational function

  • Upper and lower limit frequency setting, frequency jump operation, external thermal input selection, instantaneous power failure restart operation, forward and reverse rotation prevention, remote setting, brake sequence, second function, multi-speed operation, stop-on-contact control, droop control, regeneration avoidance, slip compensation, operation mode selection, offline auto tuning function, PID control, computer link operation (RS-485)

  • Frequency setting signal :Analog input terminal points: 2 points

  • Analog input terminal specifications :Terminal 2: 0 ~ 10V, 0 ~ 5V selectable terminal 4: 0 ~ 10V, 0 ~ 5V, 4 ~ 20mA can be selected

  • Digital input :Operation panel, input by the parameter unit

  • Start signal :Forward and reverse individual, start signal self-holding input (3-wire input) can be selected

  • input signal :Terminal points (contact input): 7 points

  • Pulse-train input :None

  • Input terminal selection possible signal :Multi-speed selection, remote setting, Atetome selection, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, brake opening completion signal, external thermal input, PU- external operation switch, V / F changeover, output stop, start self-holding selection, forward selection, reverse rotation command, inverter reset, PU-NET operation switching, external -NET change operation, command rights switching, inverter operation enable signal, from the PU operation external interlock

  • Output signal :Output terminal (open collector output) Number: 2 points

  • Output terminal (relay output) Number :1 point

  • Output pin-selectable signal :During inverter operation, frequency arrival, overload alarm, output frequency detection, regenerative brake pre-alarm, electronic thermal pre-alarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward reverse output, brake opening request, fan failure, FIN overheating pre-alarm, during a power failure deceleration, in PID control operation, during retry, life alarm, current average value monitor, remote output, minor fault output, abnormal output, abnormal output 3, maintenance timer select from the alarm

  • Output pin-selectable signal (when the option is installed) :Output the same signal as the main body

  • Output terminal points for display meter :1 point

  • Output terminal specifications for display meter :FM: up to 2.4kHz

  • Pulse train output :None

  • For meter output pin-selectable signal :Output frequency, motor current (steady), output voltage, frequency setting value, the motor torque, converter output voltage, the regenerative brake duty, electronic thermal load factor, output current peak value, the converter output voltage peak value, reference voltage output, motor load select rate, PID target value, PID measured value, from the output power. Pulse train output

  • display :control panel

  • Operating condition

  • Output frequency, motor current (steady), output voltage, frequency setting value, cumulative energization time, actual operation time, motor torque, converter output voltage, the regenerative brake duty, electronic thermal load factor, output current peak value, the converter output voltage peak value, motor load factor, PID target value, PID measured value, PID deviation, the inverter input and output terminal monitor, input and output terminal option monitor, output power, integrated power, motor thermal load factor, it can be selected from the inverter thermal load factor

  • Abnormal contents :Display an abnormal content at the time of operation of the protection function, store the 8 doses abnormal contents (protective function just before the output voltage and current, frequency and cumulative energization time)

  • Protection and alarm function :<Protection> during acceleration over-current, constant speed during the over-current, over-current during deceleration, acceleration during overvoltage, constant speed during overvoltage, during deceleration overvoltage, inverter protection thermal operation, motor protection thermal operation, fin overheat, input phase failure, startup output side earth (ground) fault overcurrent, output short circuit, output phase failure, external thermal behavior, options abnormal, parameter error, PU missing generation, the number of retries over, CPU abnormal, brake transistor abnormality, inrush resistance overheat, communication error, analog input error , USB communication error, brake sequence error 4 to 7 <alarm function> fan failure, overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter write error, regenerative brake pre-alarm, electronic thermal pre-alarm, maintenance output, undervoltage

  • environment :Ambient temperature

  • -10°C ~ + 50°C (No freezing) (-10°C ~ + 40°C when the total closure structure specification)

  • Ambient humidity :Less than 90% RH (non-condensing)

  • Storage temperature :-20°C ~ + 65°C

  • atmosphere :Indoor (no corrosive gas, flammable gas, oil mist, dust and dirt)

  • Altitude, vibration :1000m or less above sea level 5.9M · / S 2 or less

  • Shipping Weight : 2.4 Kg

  • Download PDF File FR-E740-0.4K, 415V  

RM1,288.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : FX5-16ET/ES
  • Manufacturer : Mitsubishi Electric
RM818.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : 329A3529P001
  • Manufacturer : Metrix
RM5,575.00
  • Even though we have this part in stock, it may take several days for internal process to complete. Goods will be delivered within 5 working days.
  • Input: 16 points, 12/24 VDC, 3/7 mA, response time: 10 ms, 16 points/common
  • Output: 12 points,24 VDC/240 VAC, 2 A/point, 5 A/common, response time: 12 ms, 8 points/common, 3 points/common
  • Independent contact, 36-point terminal block
  • Refurbished with 1 year warranty, original packing
  • Shipping Weight: 1.5 kg
RM1,048.80
  • Even though we have this part in stock, it may take several days for internal process to complete. Goods will be delivered within 5 working days.
  • Input: 32 points, 12/24 VDC, 3/7 mA, Response Time: 10ms, 16 points/common, positive common
  • Output: 24 points, 24 VDC/240 VAC, 2 A/point, 5 A/common, response time: 12 ms, 8 points/common
  • 36-point terminal block
  • Refurbished with 1 year warranty, original packing
  • Shipping Weight: 2.0 Kg
RM1,191.40
  • Even though we have this part in stock, it may take several days for internal process to complete. Goods will be delivered within 5 working days.
  • Input: 32 points, 12/24 VDC, 3/7 mA, response time: 10 ms, 16 points/common, positive common
  • Output: 24 points, 12/24 VDC, leakage at OFF:0.1 mA, response time: 2 ms, 8 points/common
  • With surge suppressor, 36-point terminal block
  • Refurbished with 1 year warranty, original packing
  • Shipping Weight: 1.6 kg
RM1,265.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1S68AD
  • Manufacturer : Mitsubishi Electric
RM782.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number :A1SD75P1-S3
  • Manufacturer :Mitsubishi Electric
RM1,941.00
  • Even though we have this part in stock, it may take several days for internal process to complete. Goods will be delivered within 5 working days.
  • BLANK COVER
  • REFURBISHED WITH 1 YEAR WARRANTY, ORIGINAL PACKING
  • SHIPPING WEIGHT: 1 kg
RM78.20
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SJ71QC24
  • Manufacturer : Mitsubishi Electric
RM827.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SX80
  • Manufacturer : Mitsubishi Electric
RM377.20
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SX81
  • Manufacturer : Mitsubishi Electric
RM634.80
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SY80
  • Manufacturer : Mitsubishi Electric
RM680.80
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number : A1SY81
  • Manufacturer : Mitsubishi Electric
RM524.40
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number :A2ACPU
  • Manufacturer :Mitsubishi Electric
RM1,040.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number :A3ACPU
  • Manufacturer :Mitsubishi Electric
RM1,159.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number :A616AD
  • Manufacturer :Mitsubishi Electric
RM1,633.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number :A68AD
  • Manufacturer :Mitsubishi Electric
RM1,256.00
  • Condition : Brand New
  • Warranty : 1 Years
  • Product Number :A6BAT
  • Manufacturer :Mitsubishi Electric
RM23.00
  • Estimated Delivery Time: 1 Week
  • 37-pin D-sub connector
  • Soldering type
  • Shipping Weight: 1 kg
RM87.40
  • Estimated Lead Time : 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Product No. : A6TBX36E

  • Product type : Terminal Block Converter Module

  • For negative common type input modules (standard type)

  • Applicable wire size : 0.75 to 2mm

  • Shipping Weight : 1.5 Kg

RM220.00
  • Estimated Lead Time : 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Product No. : AC30TB-E

  • Product type : Terminal Block Cable

  • Shipping Weight : 1.5 Kg

RM264.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65SBT-64AD

  • CC-Link analog-to-digital conversion

  • unit AJ65SBT-64AD

  • Number of analog input points : 4 points (4 channels)

  • Analog input Voltage : DC-10 to + 10 V (input resistance value: 1 MΩ)

  • Current : DC 0 to 20 mA (input resistance value: 250 Ω)

  • Digital output : -4096 to + 4095

  • I / O characteristics, resolution Input range : Digital output value (maximum resolution)

  • Voltage input 0 to 5 V : 0 to 4000 (1.25 mV)

  • 1 to 5 V : 0 to 4000 (1.0 mV)

  • -10 to 10 V : -4000 to 4000 (2.5 mV)

  • User range setting 1 (-10 to 10 V) -4000 to 4000 (2.5 mV)

  • User range setting 2 (0 to 5 V) : 0 to 4000 (1.0 mV)

  • Current input 0 to 20 mA : 0 to 4000 (5 μA)

  • 4 to 20 mA : 0 to 4000 (4 μA)

  • User range setting (0 to 20 mA) : 0 to 4000 (4 μA)

  • Accuracy (accuracy with respect to the maximum value of the digital output value) Ambient temperature: 25 ± 5 ° C : ± 0.2%

  • Ambient temperature: 0 to 55 ° C : ± 0.4%

  • A / D conversion speed : 1 ms / channel

  • Absolute maximum input Voltage : ± 15 V

  • Current : ± 30 mA

  • Insulation method : Communication system and analog input at one time: Photocoupler Isolated power supply system and analog input at a time Between: Photocoupler Isolated Channel: Non-Isolated

  • Withstand voltage : Power supply . Communication system all together and analog input Bulk: AC 500 V 1 minute

  • Station type : Remote device station (Ver.1 remote device station)

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 24 V (DC 20.4 to 26.4 V)

  • Current : 0.090 A (at 24 VDC)

  • Inrush current : 8.5 A, 2.3 ms or less

  • External wiring connection method : Communication part, Unit power supply part: 7 points 2 piece terminal block (M3 screw) Input / output part: 18 points Direct mounting terminal block (M3 screw)

  • External dimensions Height (H) : 50 mm

  • Width (W) : 118 mm

  • Depth (D) : 40 mm

  • mass : 0.20 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz , Amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, Amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.2 Kg

RM722.20
  • Estimated Lead Time : 7 - 10 working days.

  • Manufacturer : Mitsubishi Electric

  • Product No. : AJ65SBTB1-16DT1

  • Product type : Input/Output Combined Module

  • 8 input points DC24V(5mA) 1-wire type response time 0.2ms 

  • 8 output points DC24V(0.5A) 1-wire type transistor output terminal block type

  • Common wiring method 16 points/1 common (Terminal block single wire type) 

  • Number of stations occupied 1 station 32 points assignment (use 16 points)

  • Shipping weight : 5 Kg

RM607.20
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days

  • Manufacturer : Mitsubishi Electric

  • Number of output points : 8 points

  • Isolation method : Photocoupler

  • Rated load voltage : 100 to 240 V AC 50/60 Hz±5 %

  • Load voltage distortion rate : Within 5 %

  • Max. load voltage : 264 V AC

  • Max. load current : 0.6 A/point 2.4 A/common

  • Min. load voltage/current : 50 V AC 100 mA, 100 V AC 10 mA, 240

  • Shipping Weight : 2.5 Kg

RM925.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65VBTCU-68ADVN

  • CC-Link analog-to-digital conversion unit AJ65VBTCU-68ADVN

  • Number of analog input points : 8 points (8 channels)

  • Analog input Voltage : DC-10 to + 10 V (input resistance value: 1 MΩ)

  • Digital output : -4096 to + 4095

  • I / O characteristics, resolution Input range : Digital output value (maximum resolution)

  • Voltage input 0 to 5 V : 0 to 4000 (1.25 mV)

  • 1 to 5 V : 0 to 4000 (1.0 mV)

  • -10 to 10 V : -4000 to 4000 (2.5 mV)

  • User range setting 1 (-10 to 10 V) : -4000 to 4000 (2.5 mV)

  • User range setting 2 (0 to 5 V) : 0 to 4000 (1.0 mV)

  • Accuracy (accuracy with respect to the maximum value of the digital output value) Ambient temperature: 25 ± 5 ° C : ± 0.3%

  • Ambient temperature: 0 to 55 ° C : ± 0.2%

  • A / D conversion speed : 1 ms / channel

  • Absolute maximum input Voltage : ± 15 V

  • Insulation method : Communication system and analog input at one time: Photocoupler Isolated power supply system and analog input at one time: Transformer Isolation channel to non-insulation

  • Withstand voltage : Power supply . Communication system all together and analog input Bulk: AC 500 V 1 minute

  • Protection grade : IP 1 XB

  • Station type : Remote device station (Ver.1 remote device station or Ver.2 remote device station)

  • Number of occupied stations : Ver.1 Remote device station: 3 stations Ver.2 Remote device station: 1 station (extended cyclic setting: 4 times)

  • Unit power supply Voltage : DC 24 V (DC 20.4 to 26.4 V, ripple ratio within 5%)

  • Current : 0.10 A (24 VDC)

  • Inrush current : 4.2 A, 1.2 ms or less

  • External wiring connection method : One-touch connector for communication (sold separately) Unit power supply unit: Power supply . One touch connector for FG (sold separately) Input / output unit: One touch connector for I / O (sold separately)

  • communication cable : Ver.1.10 compatible CC-Link dedicated cable: FANC-110SBH, FA-CBL 200PSBH, CS-110

  • External dimensions Height (H) : 115 mm

  • Width (W) : 41 mm

  • Depth (D) : 67 mm

  • mass : 0.17 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.2 Kg

RM1,612.50
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65VBTCU-68DAVN

  • CC - Link Digital - Analog Conversion Unit AJ65VBTCU - 68DAVN

  • Number of analog output points : 8 points (8 channels)

  • Digital input : -4096 to + 4095

  • Analog output Voltage : DC-10 to + 10 V (external load resistance value: 2 kΩ to 1 MΩ)

  • I / O characteristics, resolution Output range : Digital input value (maximum resolution)

  • Voltage output 0 to 5 V : 0 to 4000 (1.25 mV)

  • 1 to 5 V : 0 to 4000 (1 mV)

  • -10 to 10 V : -4000 to 4000 (2.5 mV)

  • User range setting 1 (-10 to 10 V) : -4000 to 4000 (2.5 mV)

  • User range setting 2 (0 to 5 V) : 0 to 4000 (1 mV)

  • Accuracy (accuracy with respect to the maximum value of the analog output value) Ambient temperature: 25 ± 5 ° C : ± 0.2%

  • Ambient temperature: 0 to 55 ° C : ± 0.3%

  • D / A conversion speed : 1 ms / channel

  • Absolute maximum output Voltage : ± 12 V

  • Output short circuit protection : There

  • Insulation method : Communication system and analog output at one time: Photocoupler Isolated power supply system and analog output at one time: Transformer Isolation channel to non-insulation

  • Withstand voltage : Power supply . Communication system all together and analog output Batch: AC 500 V for 1 minute

  • Protection grade : IP 1 XB

  • Station type : Remote device station (Ver.1 remote device station or Ver.2 remote device station)

  • Number of occupied stations : Ver.1 Remote device station: 3 stations Ver.2 Remote device station: 1 station (extended cyclic setting: 4 times)

  • Unit power supply Voltage : DC 24 V (DC 20.4 to 26.4 V, ripple ratio within 5%)

  • Current : 0.15 A (at 24 VDC)

  • Inrush current : 4.3 A, 1.2 ms or less

  • External wiring connection method : One-touch connector for communication (sold separately) Unit power supply unit: Power supply . One touch connector for FG (sold separately) Input / output unit: One touch connector for I / O (sold separately)

  • communication cable : Ver.1.10 compatible CC-Link dedicated cable: FANC-110SBH, FA-CBL 200PSBH, CS-110

  • External dimensions Height (H) : 115 mm

  • Width (W) : 41 mm

  • Depth (D) : 67 mm

  • mass : 0.16 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.2 Kg

RM2,098.40
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • FX3U-3A-ADP

  • Analog input / output adapter FX3U - 3A - ADP

  • Analog input Analog input range Voltage input : DC 0 to 10 V (input resistance 198.7 kΩ)

  • Current input : DC 4 to 20 mA (input resistance 250 Ω)

  • Number of input channels : 2 channels

  • Absolute maximum input Voltage input : -0.5 V, +15 V

  • Current input : -2 mA, +30 mA

  • Input characteristics : Input mode (voltage / current input) can be set for each channel.

  • Digital output : 12 bit binary

  • resolution Voltage input : 2.5 mV (10 V x 1/4000)

  • Current input : 5 μA (16 mA X 1/3200)

  • Overall precision Voltage input : Ambient temperature 25 ° C ± 5 ° C ± 0.5% (± 50 mV) to full scale 10 V Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 100 mV) to full scale 10 V

  • Current input : Ambient temperature 25 ° C ± 5 ° C ± 0.5 % (± 80 μA) against full scale 16 mA Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 160 μA) for full scale 16 mA

  • A / D conversion time When FX3U / FX3UC sequencer is connected : 80 μs X Number of used input channels + 40 μs X Number of output output channels (data update every calculation cycle)

  • When FX3S / FX3G / FX3GC programmable controller is connected : 90 μs X number of used input channels + 50 μs X number of output output channels (data update every calculation cycle)

  • Insulation method : . Insulation between analog input / output section and sequencer by photo coupler . Insulation between drive power supply and analog input / output section by DC / DC converter . No isolation between each channel

  • Analog output Analog output range Voltage output : DC 0 to 10 V (external load resistance 5 k to 1 MΩ)

  • Current output : DC 4 to 20 mA (external load resistance 500 Ω or less)

  • Number of output channels : 1 channel

  • Output characteristics : Output mode (voltage / current output) can be set.

  • Digital input : 12 bit binary

  • resolution Voltage output : 2.5 mV (10 V x 1/4000)

  • Current output : 4 μA (16 mA X 1/4000)

  • Overall precision Voltage output : Ambient temperature 25 ° C ± 5 ° C ± 0.5% (± 50 mV) to full scale 10 V Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 100 mV) to full scale 10 V External load resistance (Rs) is less than 5 kΩ In addition, the following calculations increase. (It increases by 100 mV per 1%.) 47 X 100 / (Rs + 47) - 0.9 (%)

  • Current output : Ambient temperature 25 ° C ± 5 ° C ± 0.5 % (± 80 μA) against full scale 16 mA Ambient temperature 0 ° C to 55 ° C ± 1.0% (± 160 μA) for full scale 16 mA

  • D / A conversion time When FX3U / FX3UC sequencer is connected : 80 μs X Number of used input channels + 40 μs X Number of output output channels (data update every calculation cycle)

  • When FX3S / FX3G / FX3GC programmable controller is connected : 90 μs X number of used input channels + 50 μs X number of output output channels (data update every calculation cycle)

  • Insulation method : . Insulation between analog input / output section and sequencer by photo coupler . Insulation between drive power supply and analog input / output section by DC / DC converter . No isolation between each channel

  • Number of occupied I / O points : 0 point (It does not relate to the maximum input / output point number of the sequencer)

  • Application sequencer : FX3S, FX3G (Ver.1.20 or later), FX3U (Ver.2.61 or later), FX3GC, FX3UC (Ver.2.61 or later) FX3S - CNV - ADP is required for connection to FX3S. For connection to FX 3 G, FX 3 G - CNV - ADP is required. To connect to FX3U and FX3UC - 32MT - LT (-2), a function expansion board is required.

  • mass : About 0.1 Kg

  • Power supply Conversion circuit drive power supply : DC24 V + 20% -15% 90 mA Connect a 24 VDC power supply to the terminal block and supply it.

  • Interface drive power supply : DC 5 V 20 mA Internal power is supplied from the DC 5 V power supply of the basic unit.

  • Ambient temperature : 0 to 55 ° C. ... Operating -25 to 75 ° C. ..... Save

  • Relative humidity : 5 to 95% RH (noncondensing).... in operation

  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)

  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)

  • Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse

  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si

  • tor with period of 30 to 100 Hz

  • Withstand voltage : Between all terminals and ground terminal: 500 VAC for 1 minute

  • Insulation resistance : Between all terminals and ground terminal: 500 MV DC 500 MΩ or more with an insulation resistance meter

  • ground : Class D grounding (grounding resistance: 100 Ω or less)Grounding should be dedicated ground or common ground.

  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

  • Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

  • Shipping Weight : 1.1 Kg

RM2,129.80
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • FX3U-4AD-PT-ADP

  • Analog input adapter for Pt 100 type temperature sensor FX 3 U - 4 AD - PT - ADP

  • Temperature sensor . temperature control input signal : Platinum resistance temperature detector 3 wire type Pt 100 JIS C 1604 - 1997

  • Number of input channels : 4 channels

  • Rated temperature range : -50 ° C to + 250 ° C (-58

RM1,614.60
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • FX1N-1DA-BD

  • Analog output board FX1N - 1DA - BD

  • Analog output Analog output range Voltage output : DC 0 V to 10 V (external load resistance 2 kΩ to 1 MΩ)

  • Current output : DC 4 mA to 20 mA (external load resistance 500 Ω or less)

  • Number of output channels : 1 channel

  • Output characteristics : Output characteristics can not be adjusted.

  • Digital input Voltage output : 12 bit binary

  • Current output : 11 bit binary

  • resolution Voltage output : 2.5 mV (10 V x 1/4000)

  • Current output : 8 μA (16 mA X 1/2000)

  • Overall precision Voltage output : ± 1% (± 0.1 V) for full scale 10 V

  • Current output : ± 1% (± 0.16 mA) for full scale 16 mA

  • D / A conversion time : Approximately 10 ms (D / A conversion started with the END instruction, output after approximately 10 ms)

  • Insulation method : No isolation between analog input and sequencer, between channels

  • Number of occupied I / O points : 0 point (It does not relate to the maximum input / output point number of the sequencer)

  • Application sequencer : FX 1 S (V 2.0 or later), FX 1 N (V 2.0 or later)

  • Power supply : Internal power supply from the sequencer

  • Ambient temperature : 0 to 55 ° C. ... Operating -20 to 70 ° C. ... Save

  • Relative humidity : 35 to 85% RH (noncondensing)...at operation

  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : Amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)

  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)

  • Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse

  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si

  • tor with period of 30 to 100 Hz

  • Withstand voltage : Non-insulated between analog output part and PLC main body (Do not perform withstand voltage test)

  • Insulation resistance : Non-insulated between the analog output part and the programmable controller (Do not conduct the insulation resistance test)

  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

  • Use altitude : It can not be used under an environment pressurized to 2,000 m or less under atmospheric pressure. It may break down.

  • Shipping Weight : 1.5 Kg

RM450.80
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days

  • Manufacturer : Mitsubishi Electric

  • Part number : A0J2CPU

  • Control method : Stored program, repetitive operation

  • I/O control method : Direct system

  • Programming language : Language dedicated to sequence control (combined use of relay symbol type, logic symbolic language and SAP language)

  • Sequence Instruction : 21 types

  • Basic instruction : 38 types

  • Application instruction : 21 types

  • Processing speed : Sequence instruction 4.4 to 5.6μs/step

  • Memory capacity : Max, 7k steps

  • Number of I/O points : 336 points (maximum 480 points when using extension base unit)

  • Self diagnostic function : Watch dog timer error monitor, battery error

  • AC down detection blown fuse detection, etc

  • Allowable instantaneous power failure period : Within 20ms

  • Weight : 0.75 kg

  • Shipping Weight : 2.8 Kg

RM1,256.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Q2MEM-16MBA

  • Q2MEM-16MBA

  • Memory type : ATA card

  • Memory capacity after formatting : 15982 KB

  • Number of storable files : 512 pieces

  • Number of insertion and removal : 5000 times

  • Number of writes : A million times

  • External dimensions Height (H) : 45 mm

  • Width (W) : 42.8 mm

  • Depth (D) : 3.3 mm

  • mass : 15 g

  • General specification : Refer to general specifications of CPU module.

  • Shipping Weight : 1 Kg

RM2,392.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Q2MEM-32MBA

  • ATA card Q2MEM-32MBA

  • Memory type : ATA card

  • Memory capacity after formatting : 31854 KB

  • Number of storable files : 512 pieces

  • Number of insertion and removal : 5000 times

  • Number of writes : A million times

  • External dimensions Height (H) : 45 mm

  • Width (W) : 42.8 mm

  • Depth (D) : 3.3 mm

  • mass : 15 g

  • General specification : Refer to general specifications of CPU module.

  • Shipping Weight : 1 Kg

RM4,788.60
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Q2MEM-8MBA

  • ATA card Q2MEM-8MBA

  • Memory type : ATA card

  • Memory capacity after formatting : 7982 KB

  • Number of storable files : 512 pieces

  • Number of insertion and removal : 5000 times

  • Number of writes : A million times

  • External dimensions Height (H) : 45 mm

  • Width (W) : 42.8 mm

  • Depth (D) : 3.3 mm

  • mass : 15 g

  • Shipping Weight : 1.1 Kg

  • Shipping Weight : 1 Kg

RM1,794.00
  • Estimated Lead Time : In stock. Usually ships in 3-5 working days.

  • Manufacturer : Mitsubishi Electric

  • Q00JCPU

  • Basic model QCPU Q00JCPU

  • control method : Stored program iteration operation

  • Input / output control method : Refresh method (Direct access input / output possible by specifying direct access input / output (DX, DY))

  • Programming language Sequence control language : Relay symbol word, logic symbolic word, MELSAP 3 (SFC), MELSAP-L, function block, structured text (ST)

  • processing speed Sequence instructions LD X 0 : 200 ns

  • MOV D 0 D 1 : 700 ns

  • Constant scan : 1 ~ 2000 ms (Can be set in 1 ms increments)

  • Program capacity : 8K steps (32K bytes)

  • Memory capacity Program memory (drive 0) : 58 KB

  • Standard ROM (Drive 4) : 58 KB

  • Maximum number of stored files Program memory : 6

  • Standard ROM : 6

  • Intelligent functional unit Parameter Maximum setting number Initial setting : 512 pieces

  • refresh : 256 pieces

  • Number of input / output devices : 2048 points (X / Y 0 to 7 FF)

  • Number of input / output points : 256 points (X / Y 0 to FF)

  • Number of device points Internal relay [M] : Default 8192 points (M0 to 8191) (changeable)

  • Latch relay [L] : Default 2048 points (L0 to 2047) (changeable)

  • Link relay [B] : Default 2048 points (B 0 - 7 FF) (changeable)

  • Timer [T] : Default 512 points (T0 to 511) (Shared with low-speed timer / high-speed timer) (Changeable) Low-speed timer / high- speed timer specified by instruction Low-speed timer / high-speed timer measurement unit is set by parameter (low-speed timer: 1 to 1000 ms, 1 ms increment, default 100 ms) (High-speed timer: 0.1 to 100.0 ms, 0.1 ms increments, default 10.0 ms)

  • Integration timer [ST] : Default 0 point (Shared with low speed integration timer / high speed integration timer) (Changeable) Low speed integration timer / high speed integration timer specified by instruction Set the measurement unit of low speed integration timer / high speed integration timer by parameter (low speed integration timer: 1000 ms, 1 ms increment, default 100 ms) (High-speed integration timer: 0.1 to 100.0 ms, 0.1 ms increments, default 10.0 ms)

  • Counter [C] : Normal counter: default 512 points (C 0 to 511) (changeable) Interrupt counter: maximum 128 points (default 0 point, set by parameter)

  • Data register [D] : Default 11136 points (D0 to 11135) (changeable)

  • Link register [W] : Default 2048 points (W 0 to 7 FF) (changeable)

  • Annunciator [F] : Default 1024 points (F0 to 1023) (changeable)

  • Edge relay [V] : Default 1024 points (V 0 to 1023) (changeable)

  • Link special relay [SB] : 1024 points (SB 0 to 3 FF) (Device number is fixed)

  • Link special register [SW] : 1024 points (SW 0 to 3 FF) (the number of device points is fixed)

  • Step relay [S] : 2048 points (S 0 ~ 127 / block) (Device number is fixed)

  • Index register [Z] : 10 points (Z 0 ~ 9) (Device number is fixed)

  • Pointer [P] : 300 points (P 0 ~ 299) (Device number is fixed)

  • Interrupt pointer [I] : 128 points (I 0 to 127) ( Number of device points is fixed) Periodic interval of system interrupt pointer I 28 to 31 can be set by parameter. (2 to 1000 ms, 1 ms increments) Default I 28: 100 ms, I 29: 40 ms, I 30: 20 ms, I 31 : 10 ms

  • Special relay [SM] : 1024 points (SM 0 ~ 1023) (Device number is fixed)

  • Special register [SD] : 1024 points (SD 0 ~ 1023) (Device number is fixed)

  • Function input [FX] : 16 points (FX 0 to F) (Device number is fixed)

  • Function output [FY] : 16 points (FY 0 to F) (the number of device points is fixed)

  • Function register [FD] : 5 points (FD 0 ~ 4) (Device number is fixed)

  • Link direct device : J□□ \ X□□, J□□ \ Y□□, J□□ \ SB□□, J□□ \ SB□□, J□□ \ SB□□, J□□ \ SW□□, J□□ \ SW□ Device specification form for directly accessing the link device of the network unit□

  • Intelligent functional unit device : Device specification that directly accesses buffer memory of intelligent function module Format: U□□ \ G□□

  • Latch (power outage hold) range : L 0 to 2047 (default 2048 points) [latch range can be set for B, F, V, T, ST, C, D, W]

  • RUN / PAUSE contact : One point of each RUN / PAUSE contact can be set from X 0 to 7 FF

  • Clock function : Year, month, day, hour, minute, second, day of the week (leap year automatic discrimination) accuracy: -3.20 ~ + 5.27s (. TYP + 1.98s) / d at 0 °C accuracy: -2.57 ~ + 5.27s (TYP + . 2.22 s) / d at 25 ° C. Accuracy: -11.68 to +3.65 s (TYP. -2.64 s) / d at 55 ° C.

  • Allowable momentary power failure time : Within 20 ms (AC 100 V or more)

  • DC 5 V Internal current consumption : 0.26 A

  • External dimensions Height (H) : 98 mm

  • Width (W) : 244.4 mm

  • Depth (D) : 98 mm

  • mass : 0.66 Kg

  • Power supply part :

  • Input supply voltage : AC 100 to 240 V (-15% to + 10%)

  • Input frequency : 50/60 Hz ± 5%

  • Input voltage distortion ratio : Within 5%

  • Input maximum apparent power : 105VA

  • Inrush current : 40 A within 8 ms

  • Rated output current DC 5V : 3A

  • Overcurrent protection DC 5V : 3.3 A or more

  • Overvoltage protection DC 5V : 5.5 to 6.5 V

  • efficiency : 65% or more

  • Withstand voltage : Input . LG collective and output . FG all at once AC 2300 V / 1 min (altitude 0 to 2000 m)

  • Insulation resistance : Input . LG collective and output . Between FG batch, input batch and LG, batch output and FG: 500 MV DC insulation resistance meter 10 MΩ or more

  • Operation indication : LED display (normal: green lighting, abnormal: off, CPU part "POWER" LED)

  • fuse : Built-in (user replaceable)

  • Contact output unit : None

  • External wiring connection method : Screw terminal block (M3.5 screw)

  • Base part :

  • Number of input / output units : Five

  • Applicable unit : MELSEC-Q series unit

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -25 to 75 ° C

  • Ambient operating humidity : 5 to 95% RH, non condensing

  • Storage ambient humidity : 5 to 95% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Device class : Class I

  • Shipping Weight : 1.7 Kg

RM1,706.60
  • ESTIMATED DELIVERY TIME: 7 Working Days
  • Manufacturer : Mitsubishi Electric
  • Product No. : Q00CPU
  • Number of I/O points: 1024 points
  • Number of I/O device points: 2048 points
  • Program capacity: 8 k steps
  • Basic instruction processing speed (LD instruction): 0.16
RM1,545.60
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Q80BD-J71GP21S-SX

  • CC-Link IE Controller Network Interface Board Q80BD-J71GP21S-SX

  • Maximum number of links per network LB : 32 K points (32768 points, 4 K bytes)

  • LW : 128K points (131072 points, 256 Kbytes)

  • LX : 8K points (8192 points, 1 Kbyte)

  • LY : 8K points (8192 points, 1 Kbyte)

  • Maximum link points per station LB : 16 K points (16384 points, 2 K bytes), extended mode: 32 K points (32768 points, 4 K bytes)

  • LW : 16 K points (16384 points, 2 K bytes), extended mode: 128 K points (131072 points, 256 K bytes)

  • LX : 8K points (8192 points, 1 Kbyte)

  • LY : 8K points (8192 points, 1 Kbyte)

  • Transient transmission capacity : Maximum 1920 bytes

  • communication speed : 1 Gbps

  • communication cable : Optical fiber cable that meets 1000 BASE-SX standards: multimode optical fiber (GI)

  • Applicable connector : Double LC type connector

  • Laser class (JIS C 6802, IEC 60825-1) : Class 1 laser products

  • Total extension distance : 66000 m (when 120 units are connected)

  • Maximum Inter-Station Distance : 550 m

  • Maximum number of connected stations : 120 units (management station: 1 unit, normal station: 119 units)

  • Maximum number of networks : 239

  • Maximum number of groups : 32

  • Communication method : Token ring method

  • Transmission path format : Double loop

  • External power supply Voltage : DC 20.4 to 31.2 V

  • Current : 0.27 A

  • Allowable momentary power failure time : 1 ms (level PS 1)

  • Number of installable sheets : Up to 4 sheets

  • Mounting slot : PCI slot or PCI-X slot (half size)

  • Number of occupied slots : 1

  • DC 5 V Internal current consumption : 1.10 A

  • mass : 0.14 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -25 to 75 ° C

  • Ambient operating humidity : 5 to 95% RH, non condensing

  • Storage ambient humidity : 5 to 95% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.2 Kg

RM12,452.20
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • QJ71GP21S-SX

  • CC-Link IE Controller Network Unit QJ71GP21S-SX

  • Maximum number of links per network LB : 32 K points (32768 points, 4 K bytes)

  • LW : 128K points (131072 points, 256 Kbytes)

  • LX : 8K points (8192 points, 1 Kbyte)

  • LY : 8K points (8192 points, 1 Kbyte)

  • Maximum link points per station LB : 16 K points (16384 points, 2 K bytes), extended mode: 32 K points (32768 points, 4 K bytes)

  • LW : 16 K points (16384 points, 2 K bytes), extended mode: 128 K points (131072 points, 256 K bytes)

  • LX : 8K points (8192 points, 1 Kbyte)

  • LY : 8K points (8192 points, 1 Kbyte)

  • Transient transmission capacity : Maximum 1920 bytes

  • communication speed : 1 Gbps

  • communication cable : Optical fiber cable that meets 1000 BASE-SX standards: multimode optical fiber (GI)

  • Applicable connector : Double LC type connector

  • Laser class (JIS C 6802, IEC 60825-1) : Class 1 laser products

  • Total extension distance : 66000 m (when 120 units are connected)

  • Maximum Inter-Station Distance : 550 m

  • Maximum number of connected stations : When the management station is the universal model QCPU: 120 (management station: 1 unit, normal station: 119 units) When the management station is a high performance model QCPU: 64 units (management station: 1 unit, normal station: 63 units)

  • Maximum number of networks : 239

  • Maximum number of groups : 32

  • Communication method : Token ring method

  • Transmission path format : Double loop

  • External power supply Voltage : DC 20.4 to 31.2 V

  • Current : 0.28 A

  • Allowable momentary power failure time : 1 ms (level PS 1)

  • Number of occupied I / O points : 48 points, 2 slots (I / O assignment: free 16 points + intelli 32 points)

  • DC 5 V Internal current consumption : 0.90 A

  • External dimensions Height (H) : 98 mm

  • Width (W) : 55.2 mm

  • Depth (D) : 90 mm

  • mass : 0.28 Kg

  • Shipping Weight : 1.3 Kg

RM8,795.20
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BT-64RD4

  • CC-Link platinum resistance temperature detector Pt 100 temperature input unit AJ65BT-64RD4

  • Number of channels : 4 channels

  • Digital output Temperature measurement value : 16-bit signed binary (-1800 to 6000: value to the first decimal place X 10 times) 32-bit signed binary (-180000 to 600000: value up to the third decimal place X 1000 times)

  • Measuring method : 4 wire type

  • Usable resistance temperature detector : Pt 100, JPt 100

  • Measurement temperature range Pt 100 : -180 to 600 ° C

  • JPt 100 : -180 to 600 ° C

  • Output current for temperature detection : 1 mA

  • resolution : 0.025 °C

  • Overall accuracy (accuracy with respect to maximum value) Ambient temperature: 25 ± 5 ° C : ± 0.1%

  • Ambient temperature: 20 ° C or less, 30 ° C or more : ± 0.25%

  • Conversion speed : 40 ms / channel

  • Insulation method : Between platinum resistance temperature detector input and CC-Link transmission system: Photocoupler isolation Channel to non-insulation

  • Withstand voltage : Between power supply system batch and earth, power supply system batch and communication system batch, communication system batch and temperature input batch, between temperature input batch and ground: AC 500 V for 1 minute

  • Insulation resistance : Between power supply system batch and earth, power supply system batch and communication system batch, between communication system batch and temperature input batch, between temperature input batch and ground: 500 MV with insulation resistance meter 10 MΩ or more

  • Station type : Remote device station (Ver.1 remote device station)

  • Number of occupied stations : 4 stations

  • Unit power supply Voltage : DC 24 V (DC 18 to 30 V)

  • Current : 0.17 A

  • Allowable momentary power failure time : 1 ms

  • External wiring connection method : Communication unit, Unit power supply unit: 7 points 2-piece terminal block (M3.5 screw) I / O section: 27 points 2 piece terminal block (M3.5 screw)

  • communication cable : CC-Link dedicated cable

  • External dimensions Height (H) : 65 mm

  • Width (W) : 151.9 mm

  • Depth (D) : 63 mm

  • mass : 0.38 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz , Amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, Amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.4 Kg

RM2,687.50
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BT-64RD3

  • CC-Link platinum resistance temperature detector Pt100 temperature input unit AJ65BT-64RD3

  • Number of channels : 4 channels

  • Digital output Temperature measurement value : 16-bit signed binary (-1800 to 6000: value to the first decimal place X 10 times) 32-bit signed binary (-180000 to 600000: value up to the third decimal place X 1000 times)

  • Measuring method : 3 wire type

  • Usable resistance temperature detector : Pt 100, JPt 100

  • Measurement temperature range Pt 100 : -180 to 600 ° C

  • JPt 100 : -180 to 600 ° C

  • Output current for temperature detection : 1 mA

  • resolution : 0.025 °C

  • Overall accuracy (accuracy with respect to maximum value) Ambient temperature: 25 ± 5 ° C : ± 0.1%

  • Ambient temperature: 20 ° C or less, 30 ° C or more : ± 0.25%

  • Conversion speed : 40 ms / channel

  • Insulation method : Between platinum resistance temperature detector input and CC-Link transmission system: Photocoupler isolation Channel to non-insulation

  • Withstand voltage : Between power supply system batch and earth, power supply system batch and communication system batch, communication system batch and temperature input batch, between temperature input batch and ground: AC 500 V for 1 minute

  • Insulation resistance : Between power supply system batch and earth, power supply system batch and communication system batch, between communication system batch and temperature input batch, between temperature input batch and ground: 500 MV with insulation resistance meter 10 MΩ or more

  • Station type : Remote device station (Ver.1 remote device station)

  • Number of occupied stations : 4 stations

  • Unit power supply Voltage : DC 24 V (DC 18 to 30 V)

  • Current : 0.17 A

  • Allowable momentary power failure time : 1 ms

  • External wiring connection method : Communication unit, Unit power supply unit: 7 points 2-piece terminal block (M3.5 screw) I / O section: 27 points 2 piece terminal block (M3.5 screw)

  • communication cable : CC-Link dedicated cable

  • External dimensions Height (H) : 65 mm

  • Width (W) : 151.9 mm

  • Depth (D) : 63 mm

  • mass : 0.38 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz , Amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, Amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.4 Kg

RM2,687.50
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BT-D75P2-S3

  • CC-Link Positioning Unit (Open Collector Output Type) AJ65BT-D75P2-S3

  • Number of control axes : 2 axes

  • Interpolation function : 2 axis linear interpolation 2 axis circular interpolation

  • control method : PTP (Point To Point) control trajectory control (both linear and arc configurable) Speed ??control Speed ??/ position switching control

  • Control unit : mm, inch, degree, pulse

  • Positioning data : 600 data / axis

  • backup : Parameter and positioning data can be saved in flash ROM (battery less)

  • Positioning Positioning method PTP control : Increment method / absolute method

  • Speed ??/ position switching control : Increment method / absolute method

  • Trajectory control : Increment method / absolute method

  • Positioning range Absolute method : Standard mode ? -214748364.8 to 214748364.7 μm ? -21474.83648 to 21474.83647 inch ? 0 to 359.99999 degree ? -2147483648 to 2147483647 pulse stepping motor mode ? -13421772.8 to 13421772.7 μm ? -1342.17728 to 1342.17727 inch ? 0 to 359.99999 degree ? -134217728 to 134217727 pulse

  • Increment method : Standard mode ? -214748364.8 to 214748364.7 μm ? -21474.83648 to 21474.83647 inch ? -21474.83648 to 21474.83647 degree ? -2147483648 to 2147483647 pulse stepping motor mode ? -13421772.8 to 13421772.7 μm ? -1342.17728 to 1342.17727 inch ? -1342.17728 to 1342.17727

RM2,472.50
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BTB2-16DR

  • CC-Link remote I / O unit (DC input / contact output, terminal block) AJ65BTB2-16DR

  • Input specification :

  • Input format : DC input (plus common / minus common common type)

  • Number of input points : 8 points

  • Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 28.8 V)

  • Rated input current : About 7 mA

  • Maximum number of simultaneous input points : 100%

  • ON voltage / ON current : 14 V or more / 3.5 mA or more

  • OFF voltage / OFF current : 6 V or less / 1.7 mA or less

  • Input resistance : About 3.3 kΩ

  • Input response time OFF → ON : 10 ms or less

  • ON → OFF : 10 ms or less

  • Input common type : 8 points / common (terminal trapezoid 2 wire type)

  • Input isolation method : Photocoupler isolation

  • Number of output points : 8 points

  • Rated switching voltage / current : DC 24 V 2A (resistance load) / 1 point, AC 240 V 2 A (cos φ = 1) / 1 point, 8 A / 1 common

  • Minimum opening / closing load : DC 5 V 1 mA

  • Maximum switching voltage : AC 250V DC 110V

  • lifespan mechanical : Over 20 million times

  • Electrical : Rated switching voltage . current load: 100,000 times or more AC 200 V 1.5 A, AC 240 V 1A (COS φ = 0.7): 100 thousand times or more AC 200 V 1A, AC 240 V 0.5 A (COS φ = 0.35): 100,000 times or more DC 24 V 1A, DC 100 V 0.1 A L / R = 7 ms): 100 thousand times or more

  • Maximum switching frequency : 3600 times / hour

  • Output response time OFF → ON : 10 ms or less

  • ON → OFF : 12 ms or less

  • Surge suppressor : None

  • Output section External power supply Voltage : DC 24 V ± 10% (ripple voltage 4 V pp or less)

  • Current : 45 mA or less (TYP. DC 24 V, all points ON)

  • Output common method : 8 points / common (terminal trapezoid 2 wire type)

  • Output isolation method : Photocoupler isolation

  • Withstand voltage : Between AC external terminal and ground: AC 1500 V 1 min DC external terminal Between ground and ground: AC 500 V 1 min

  • Insulation resistance : AC external terminal all together and ground, DC external terminal collective to ground: 500 MV DC insulation resistance meter 10 MΩ or more

  • Station type : Remote I / O station

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 24 V (ripple ratio within 5%) (allowable voltage range DC 15.6 to 28.8 V)

  • Current : 70 mA or less (TYP. At 24 VDC)

  • External wiring connection method : Communication part, Unit power supply part: 7 points 2 piece terminal block (M3.5 screw) I / O power supply part, input / output part: 37 points 2 piece terminal block (M3.5 screw)

  • External dimensions Height (H) : 65 mm

  • Width (W) : 197.4 mm

  • Depth (D) : 46 mm

  • mass : 0.43 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.4 Kg

RM1,410.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BTB1-16DT

  • CC-Link remote I / O unit (DC input / transistor output, terminal block) AJ65BTB1-16DT

  • Input specification :

  • Input format : DC input (plus common type)

  • Number of input points : 8 points

  • Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 28.8 V)

  • Rated input current : About 7 mA

  • Maximum number of simultaneous input points : 100%

  • ON voltage / ON current : 14 V or more / 3.5 mA or more

  • OFF voltage / OFF current : 6 V or less / 1.7 mA or less

  • Input resistance : About 3.3 kΩ

  • Input response time OFF → ON : 10 ms or less

  • ON → OFF : 10 ms or less

  • Input common type : 8 points / common (terminal trapezoid 1 wire type)

  • Input isolation method : Photocoupler isolation

  • Output format : Transistor output (sink type)

  • Number of output points : 8 points

  • Rated load voltage : DC12 / 24V (ripple ratio within 5%)

  • Used load voltage range : DC 10.2 to 28.8 V

  • Maximum load current : 0.5 A / 1 point, 4 A / 1 common

  • Maximum inrush current : 4 A 10 ms or less

  • Leakage current at OFF : 0.1 mA or less

  • Maximum voltage drop during ON : DC 0.9 V or less (TYP.) 0.5 A, DC 1.5 V or less (MAX.) 0.5 A

  • Output response time OFF → ON : 2 ms or less

  • ON → OFF : 2 ms or less (resistance load)

  • Surge suppressor : Zener diode

  • Output section External power supply Voltage : DC 12/24 V (ripple ratio within 5%) (allowable voltage range DC 10.2 to 28.8 V)

  • Current : 50 mA or less (TYP. DC 24 V, per common) External load current is not included

  • Output common method : 8 points / common (terminal trapezoid 1 wire type)

  • Output isolation method : Photocoupler isolation

  • Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

  • Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more

  • Station type : Remote I / O station

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 24 V (ripple ratio within 5%) (allowable voltage range DC 15.6 to 28.8 V)

  • Current : 70 mA or less (TYP. At 24 VDC)

  • External wiring connection method : Communication part, Unit power supply part: 7 points 2 piece terminal block (M3.5 screw) I / O power supply part, input / output part: 27 points 2 piece terminal block (M3.5 screw)

  • External dimensions Height (H) : 65 mm

  • Width (W) : 151.9 mm

  • Depth (D) : 46 mm

  • mass : 0.33 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.3 Kg

RM645.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BTB1-16D

  • CC-Link remote I / O unit (DC input, terminal block) AJ65BTB1-16D

  • Input format : DC input (plus common / minus common common type)

  • Number of input points : 16 points

  • Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 28.8 V)

  • Rated input current : About 7 mA

  • Maximum number of simultaneous input points : 100%

  • ON voltage / ON current : 14 V or more / 3.5 mA or more

  • OFF voltage / OFF current : 6 V or less / 1.7 mA or less

  • Input resistance : About 3.3 kΩ

  • Input response time OFF → ON : 10 ms or less

  • ON → OFF : 10 ms or less

  • Input common type : 16 points 1 common (terminal trapezoid 1 wire type)

  • Input isolation method : Photocoupler isolation

  • Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

  • Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more

  • Station type : Remote I / O station

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 24 V (ripple ratio within 5%) (allowable voltage range DC 15.6 to 28.8 V)

  • Current : 60 mA or less (TYP. At 24 VDC)

  • External wiring connection method : Communication part, Unit power supply part: 7 points 2 piece terminal block (M3.5 screw) I / O power supply part, input / output part: 27 points 2 piece terminal block (M3.5 screw)

  • External dimensions Height (H) : 65 mm

  • Width (W) : 151.9 mm

  • Depth (D) : 46 mm

  • mass : 0.32 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.3 Kg

RM645.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65SBT-RPT

  • CC-Link repeater (T branch) unit AJ65SBT-RPT

  • Transmission speed : 156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps (selectable)

  • Maximum number of connected stages : AJ65SBT-RPT only: Combination of 10-stage AJ65SBT-RPT and AJ65SBT-RPS: combination of 4-stage AJ65 SBT-RPT, AJ65 FBTA-RPH, AJ65 BTS-RPH, AJ 65 SBT RPG and AJ 65 BT-RPI: 3 steps

  • Maximum transmission distance of each segment : Different according to transmission speed

  • Maximum number of connected units : 64 units

  • Number of occupied stations : 0 (None)

  • Station number : No station number

  • Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

  • Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more

  • External wiring connection method : Communication unit, Unit power supply unit: 7 point 2-piece terminal block (M3.5 screw)

  • Unit power supply Voltage : DC 20.4 to 26.4 V

  • Current : 60.0 mA (TYP. At 24 VDC)

  • External dimensions Height (H) : 50 mm

  • Width (W) : 87.3 mm

  • Depth (D) : 40 mm

  • mass : 0.2 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.2 Kg

RM699.20
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65SBTB2N-16R

  • CC-Link small type remote I / O unit (contact output, terminal block) AJ65SBTB2N-16R

  • Number of output points : 16 points

  • Rated switching voltage / current : DC 24 V 2A (resistance load) / 1 point, AC 240 V 2 A (cos φ = 1) / 1 point, 8 A / 1 common

  • Minimum opening / closing load : DC 5 V 1 mA

  • Maximum switching voltage : AC 264 V DC 125 V

  • lifespan mechanical : Over 20 million times

  • Electrical : Rated switching voltage . current load: 100,000 times or more AC 200 V 1.5 A, AC 240 V 1A (COS φ = 0.7): 100 thousand times or more AC 200 V 1A, AC 240 V 0.5 A (COS φ = 0.35): 100,000 times or more DC 24 V 1A, DC 100 V 0.1 A L / R = 7 ms): 100 thousand times or more

  • Maximum switching frequency : 3600 times / hour

  • Output response time OFF → ON : 10 ms or less

  • ON → OFF : 12 ms or less

  • Output common method : 16 points 1 common (terminal trapezoid 2 wire type)

  • Output isolation method : Relay insulation

  • Withstand voltage : Between AC external terminal and ground: AC 2830 Vrms / 3 cycles (altitude 2000 m) Between DC external terminals and ground: AC 500 V 1 min

  • Insulation resistance : AC external terminal all together and ground, DC external terminal collective to ground: 500 MV DC insulation resistance meter 10 MΩ or more

  • Station type : Remote I / O station

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 20.4 to 26.4 V (ripple ratio within 5%)

  • Current : 120 mA or less (24 VDC, all points ON)

  • External wiring connection method : Communication part, unit power supply part: 7 points 2 piece terminal block (M3 screw) I / O power supply part, input / output part: 34 points Direct mounting terminal block (M3 screw)

  • External dimensions Height (H) : 50 mm

  • Width (W) : 179 mm

  • Depth (D) : 40 mm

  • mass : 0.35 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 2 Kg

RM727.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65VBTCE32-16DT

  • CC-Link small type remote I / O unit (DC input / transistor output, sensor connector (e-CON)) AJ65VBTCE 32-16DT

  • Input format : DC input (plus common type)

  • Number of input points : 8 points

  • Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 26.4 V)

  • Rated input current : About 5 mA

  • Maximum number of simultaneous input points : 100%

  • ON voltage / ON current : 14 V or more / 3.5 mA or more

  • OFF voltage / OFF current : 6 V or less / 1.7 mA or less

  • Input resistance : About 4.7 kΩ

  • Input response time OFF → ON : 1.5 ms or less (24 VDC)

  • ON → OFF : 1.5 ms or less (24 VDC)

  • Input isolation method : Photocoupler isolation

  • Output format : Transistor output (sink type)

  • Number of output points : 8 points

  • Rated load voltage : DC 24V

  • Used load voltage range : DC 19.2 to 26.4 V (ripple ratio within 5%)

  • Maximum load current : 0.1 A / 1 point, 0.8 A / 1 common

  • Maximum inrush current : 0.7 A less than 10 ms

  • Leakage current at OFF : 0.1 mA or less

  • Maximum voltage drop during ON : DC 0.1 V or less (TYP.) 0.1 A, DC 0.2 V or less (MAX.) 0.1 A

  • Output response time OFF → ON : 1ms or less

  • ON → OFF : 1 ms or less (resistance load)

  • Surge suppressor : Zener diode

  • Protection function : Overload protection function, overvoltage protection function, overheat protection function

  • Output section External power supply Voltage : DC 19.2 to 26.4 V (ripple ratio within 5%)

  • Current : 5 mA or less (24 VDC, when all points are ON) External load current is not included

  • Output isolation method : Photocoupler isolation

  • Common method : 16 points 1 common (Input: sensor connector (e-CON) type 3 wire type, output: sensor connector (e-CON type 2 wire type)

  • Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

  • Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more

  • Protection grade : IP 1 XB

  • Station type : Remote I / O station

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 20.4 to 26.4 V (ripple ratio within 5%)

  • Current : 40 mA or less (24 VDC, all points ON)

  • External wiring connection method : Communication unit: One-touch connector for communication (sold separately) Unit power supply unit, I / O power supply unit: Power supply . FG one-touch connector (sold separately) Input / output unit: sensor connector (e-CON)

  • communication cable : Ver.1.10 compatible CC-Link dedicated cable: FANC-110SBH, FA-CBL 200PSBH, CS-110

  • External dimensions Height (H) : 50 mm

  • Width (W) : 100 mm

  • Depth (D) : 45.5 mm

  • mass : 0.11 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.2 Kg

RM967.50
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65VBTCE32-32DT

  • CC-Link small type remote I / O unit (DC input / transistor output, sensor connector (e-CON)) AJ65VBTCE 32-32DT

  • Input specification :

  • Input format : DC input (plus common type)

  • Number of input points : 16 points

  • Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 26.4 V)

  • Rated input current : About 5 mA

  • Maximum number of simultaneous input points : 100%

  • ON voltage / ON current : 14 V or more / 3.5 mA or more

  • OFF voltage / OFF current : 6 V or less / 1.7 mA or less

  • Input resistance : About 4.7 kΩ

  • Input response time OFF → ON : 1.5 ms or less (24 VDC)

  • ON → OFF : 1.5 ms or less (24 VDC)

  • Input isolation method : Photocoupler isolation

  • Output format : Transistor output (sink type)

  • Number of output points : 16 points

  • Rated load voltage : DC 24V

  • Used load voltage range : DC 19.2 to 26.4 V (ripple ratio within 5%)

  • Maximum load current : 0.1 A / 1 point, 1.6 A / 1 common

  • Maximum inrush current : 0.7 A less than 10 ms

  • Leakage current at OFF : 0.1 mA or less

  • Maximum voltage drop during ON : DC 0.1 V or less (TYP.) 0.1 A, DC 0.2 V or less (MAX.) 0.1 A

  • Output response time OFF → ON : 1ms or less

  • ON → OFF : 1 ms or less (resistance load)

  • Surge suppressor : Zener diode

  • Protection function : Overload protection function, overvoltage protection function, overheat protection function

  • Output section External power supply Voltage : DC 19.2 to 26.4 V (ripple ratio within 5%)

  • Current : 10 mA or less (24 VDC, when all points are ON) External load current is not included

  • Output isolation method : Photocoupler isolation

  • Common method : 32 inputs 1 common (Input: sensor connector (e - CON) type 3 wire type, output: sensor connector (e - CON type 2 wire type)

  • Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

  • Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more

  • Protection grade : IP 1 XB

  • Station type : Remote I / O station

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 20.4 to 26.4 V (ripple ratio within 5%)

  • Current : 45 mA or less (24 VDC, all points ON)

  • External wiring connection method : Communication unit: One-touch connector for communication (sold separately) Unit power supply unit, I / O power supply unit: Power supply . FG one-touch connector (sold separately) Input / output unit: sensor connector (e-CON)

  • communication cable : Ver.1.10 compatible CC-Link dedicated cable: FANC-110SBH, FA-CBL 200PSBH, CS-110

  • External dimensions Height (H) : 50 mm

  • Width (W) : 155 mm

  • Depth (D) : 45.5 mm

  • mass : 0.16 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.2 Kg

RM1,075.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65VBTS32-32DT

  • CC-Link small type remote I / O unit (DC input / transistor output, spring clamp terminal block) AJ65VBTS 32-32DT

  • Input specification :

  • Input format : DC input (plus common type)

  • Number of input points : 16 points

  • Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 26.4 V)

  • Rated input current : About 5 mA

  • Maximum number of simultaneous input points : 100% (when mounted on the front), see the derating chart except when front mounted

  • ON voltage / ON current : 14 V or more / 3.5 mA or more

  • OFF voltage / OFF current : 6 V or less / 1.7 mA or less

  • Input resistance : About 4.7 kΩ

  • Input response time OFF → ON : 1.5 ms or less (24 VDC)

  • ON → OFF : 1.5 ms or less (24 VDC)

  • Input common type : 16 points 1 common (Spring clamp terminal trapezoid 3 wire type)

  • Input isolation method : Photocoupler isolation

  • Output format : Transistor output (sink type)

  • Number of output points : 16 points

  • Rated load voltage : DC12 / 24V

  • Used load voltage range : DC 10.2 to 26.4 V (ripple ratio within 5%)

  • Maximum load current : 0.5 A / 1 point, 4 A / 1 common

  • Maximum inrush current : 1.0 A less than 10 ms

  • Leakage current at OFF : 0.1 mA or less

  • Maximum voltage drop during ON : DC 0.3 V or less (TYP.) 0.5 A, DC 0.6 V or less (MAX.) 0.5 A

  • Output response time OFF → ON : 1ms or less

  • ON → OFF : 1 ms or less (resistance load)

  • Surge suppressor : Zener diode

  • Output section External power supply Voltage : DC 10.2 to 26.4 V (ripple ratio within 5%)

  • Current : 30 mA or less (24 VDC, when all points are ON) External load current is not included

  • Output common method : 16 points 1 common (Spring clamp terminal trapezoid 2 wire type)

  • Output isolation method : Photocoupler isolation

  • Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

  • Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more

  • Protection grade : IP 1 XB

  • Station type : Remote I / O station

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 20.4 to 26.4 V (ripple ratio within 5%)

  • Current : 50 mA or less (24 VDC, all points ON)

  • External wiring connection method : Communication unit: One-touch connector for communication (sold separately) Unit power supply unit, input / output power supply unit: Power supply . FG one-touch connector (sold separately) Input / output unit: 2 piece spring clamp terminal block

  • communication cable : Ver.1.10 compatible CC-Link dedicated cable: FANC-110SBH, FA-CBL 200PSBH, CS-110

  • External dimensions Height (H) : 50 mm

  • Width (W) : 222 mm

  • Depth (D) : 51.5 mm

  • mass : 0.41 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.4 Kg

RM1,075.00
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65SBTB1-32DT3

  • CC-Link small type remote I / O unit (DC input / transistor output, terminal block) AJ65SBTB 1-32DT3

  • Input format : DC input (plus common type)

  • Number of input points : 16 points

  • Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 26.4 V)

  • Rated input current : About 5 mA

  • Maximum number of simultaneous input points : 100%

  • ON voltage / ON current : 15 V or more / 3 mA or more

  • OFF voltage / OFF current : 3 V or less / 0.5 mA or less

  • Input resistance : About 4.7 kΩ

  • Input response time OFF → ON : 0.2 ms or less (24 VDC)

  • ON → OFF : 0.2 ms or less (24 VDC)

  • Input isolation method : Photocoupler isolation

  • Output format : Transistor output (sink type)

  • Number of output points : 16 points

  • Rated load voltage : DC 24V

  • Used load voltage range : DC 19.2 to 26.4 V (ripple ratio within 5%)

  • Maximum load current : 0.5 A / 1 point, 3.6 A / 1 common

  • Maximum inrush current : 1.0 A less than 10 ms

  • Leakage current at OFF : 0.1 mA or less

  • Maximum voltage drop during ON : DC 0.3 V or less (TYP.) 0.5 A, DC 0.6 V or less (MAX.) 0.5 A

  • Output response time OFF → ON : 0.5ms or less

  • ON → OFF : 1.5 ms or less (resistance load)

  • Surge suppressor : Zener diode

  • Output section External power supply Voltage : DC 19.2 to 26.4 V (ripple ratio within 5%)

  • Current : 24.2 mA or less (24 VDC, when all points are ON) External load current is not included

  • Output isolation method : Photocoupler isolation

  • Common method : 32 points 1 common (terminal trapezoid 1 wire type)

  • Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute

  • Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more

  • Protection grade : IP2X

  • Station type : Remote I / O station

  • Number of occupied stations : 1 station

  • Unit power supply Voltage : DC 20.4 to 26.4 V (ripple ratio within 5%)

  • Current : 60 mA or less (24 VDC, all points ON)

  • External wiring connection method : Communication part, unit power supply part: 7 points 2 piece terminal block (M3 screw) I / O power supply part, input / output part: 34 points Direct mounting terminal block (M3 screw)

  • External dimensions Height (H) : 50 mm

  • Width (W) : 179 mm

  • Depth (D) : 40 mm

  • mass : 0.25 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.3 Kg

RM989.00