- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E740-0.4K-CHT
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E740-0.75k-CHT
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E740-1.5K-CHT
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E740-11K-CHT
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E740-15K-CHT
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E740-2.2K-CHT
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E740-3.7K-CHT
- Manufacturer : Mitsubishi Electric
- Estimated Lead Time : 7 - 10 working days.
- Manufacturer : Mitsubishi Electric
- Product No. : FR-E740-5.5K
- Product type : Inverter Drive
- Applicable motor capacity(kW) : 5.5
- Input voltage class : Three-phase 400V
- Output specification : Three-phase
- Output capacity(kVA) : 9.1
- External communications : RS-232/422/485
- Representative standard: CE / UL / CU
- Shipping weight : 5Kg
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E740-5.5K-CHT
- Manufacturer : Mitsubishi Electric
-
Estimated Lead Time : In stock. Usually ships in 7-10 working days
-
Manufacturer : Mitsubishi Electric
-
Product series : FREQROL-E700
-
type : Simple and Powerful Compact Inverter FREQROL-E700 Series Three-phase 400 V
-
Product name : FR-E740-7.5K
-
Applicable motor capacity (kW) : 7.5 kW
-
output Rated capacity (kVA) : 13
-
Rated current (A) : 17
-
Overload current rating : 150% 60s, 200% 3s (retarding time characteristics)
-
Voltage : Three-phase 380 to 480 V
-
Regenerative braking torque Maximum value / Permissible usage rate : -
-
Power supply Voltage class : Three-phase 400 V class
-
Rated input AC voltage / frequency : Three-phase 380 to 480 V 50 Hz / 60 Hz
-
AC voltage tolerance fluctuation : 325 to 528 V 50 Hz / 60 Hz
-
Frequency tolerance fluctuation :
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E740-7.5K-CHT
- Manufacturer : Mitsubishi Electric
-
Condition : Brand New
-
Warranty : 1 Year
-
Part Number : FR-E820S-0008-4-60
-
Manufacturer : Mitsubishi Electric
-
Condition : Brand New
-
Warranty : 1 Year
-
Part Number : FR-E820S-0015-4-60
-
Manufacturer : Mitsubishi Electric
-
Condition : Brand New
-
Warranty : 1 Year
-
Part Number : FR-E820S-0030-4-60
-
Manufacturer : Mitsubishi Electric
-
Condition : Brand New
-
Warranty : 1 Year
-
Part Number : FR-E820S-0050-4-60
-
Manufacturer : Mitsubishi Electric
-
Condition : Brand New
-
Warranty : 1 Year
-
Part Number : FR-E820S-0080-4-60
-
Manufacturer : Mitsubishi Electric
-
Condition : Brand New
-
Warranty : 1 Year
-
Part Number : FR-E820S-0110-4-60
-
Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E840-0016-4-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E840-0026-4-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E840-0040-4-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E840-0060-4-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E840-0095-4-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E840-0170-4-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E840-0230-4-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E840-0230-4-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E840-0380-4-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-E840-0440-4-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F740-45K-CHT1
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00038-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00052-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00083-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00126-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00170-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00250-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00310-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00380-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00470-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00620-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00770-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-00930-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-01160-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-01260-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-01800-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-02160-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-02600-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-03250-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-03610-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-F840-04320-2-60
- Manufacturer : Mitsubishi Electric
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FR-LU08
- Manufacturer : Mitsubishi Electric
Estimated Lead Time : In stock. Usually ships in 7-10 working days.
Manufacturer : Mitsubishi Electric
FX1S-10MR-001
FX 1 S series FX 1 S - 10 MR
Arithmetic control method : Stored program iterative calculation method with interrupt instruction
Input / output control method : Batch processing method (when END instruction is executed), I / O refresh command, with pulse catch function
Programming language : Relay symbol method + step ladder method (SFC expressible)
Program memory Maximum memory capacity : 2000 step comment, up to 2000 steps including file register
Internal memory capacity / format : 2000 step EEPROM (memory backup not required)
Memory cassette (memory board) : FX1N-EEPROM-8L (8000 step EEPROM: FX1S can only use 2000 steps)
Write function during RUN : Yes (program changeable during sequencer RUN)
Protection function : With password protection function (by keyword function)
Real time clock Clock function : Built-in 1980 to 2079 (with leap year correction) 2-digit / 4-digit year AD changeable, monthly difference ± 45 seconds (25 ° C) ※ Note on clock function The current time of the built- It is backed up with. The large capacity condenser (built-in) is fully charged at the energization time of 30 minutes and holds the present value for 10 days.
Types of instructions Basic instruction : . Sequence instruction: 27 pieces . Step ladder command: 2 pieces
Application instruction : Application instruction: 85 species
Arithmetic processing speed Basic instruction : 0.55 to 0.7 μs / instructions
Application instruction : 3.7 to several 100 μs / instructions
Number of input / output points Number of input points : 16 points or less (according to input specifications) can not be added
Number of output points : 14 points or less (due to output specification) Can not be added
Total score : 30 points or less (according to input / output specification) can not be added
device I / O relay Input relay : X000 to X017 16 points (octal number) can not be expanded (FX1S - 10M□ corresponds to the range from X000 to X005)
Output relay : Y000 - Y015 14 points (octal number) can not be expanded (FX1S - 10M□ corresponds to Y000 - Y003 range)
Auxiliary relay For general use : M 0 to M 383 384 points
For keeping : M384 to M511 128 points ※ Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.
Special purpose : M8000 to M8255 256 points
State Initial state : S0 to S9 10 points
For keeping : All points of power failure hold (S 0 to S 127) * Note on keep area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.
Timer (on-delay) 100 ms : T 0 to T 62 63 points (0.1 to 3,276.7 seconds)
10 ms : When M8028 is turned ON, T32 to T62 (31 points) can be changed to 10ms timer (0.01 to 327.67 seconds)
1 ms : T63 1 point (0.001 to 32.767 seconds)
Other : Two internal analog volume can be used as analog timer VR 1: D 8030, VR 2: D 8031 ??2 points (0 to 255)
counter 16 bit up : C 0 to C 15 16 points (0 to 32,767 counts)
16 bit up (keep) : C16 to C31 16 points (0 to 32,767 counts) (EEPROM keeping) * Note on keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.
High speed counter : [32-bit high-speed up / down (EEPROM keep)] C235 to C255 1 phase: 60 kHz, 10 kHz 2 phases: 30 kHz, 5 kHz There are restrictions on the number of points and input frequencies that can be used depending on the conditions used. ※ Note on Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.
Data register (32 bits in pair use) For 16-bit general purpose : D0 to D127 128 points
For 16 bit keeping : D 128 - D 255 128 points (EEPROM keep) * Note on keep area Keep area and non-keep area are fixed. (Parameter can not be changed.) In order to reliably keep to EEPROM, it is necessary for the sequencer to be energized for at least 5 consecutive minutes.
File register (keep) : D 1000 - D 2499 1500 points (File register can be set in 500 points units) (EEPROM keep)
16 bit special use : D 8000 to D 8255 256 points
For 16 bit index : V 0 to V 7, Z 0 to Z 7 16 points
Pointer JUMP, for CALL branch : P0 to P63 64 points (for CJ instruction, CALL instruction, P63 for END jump)
Input interrupt : I00□ ~ I50□ 6 points
nesting : [For master control] N 0 to N 7 8 points (for MC command)
constant Decimal number (K) : 16 bits: -32,768 to + 32,767 32 bits: -2, 147, 483, 648 to +2, 147, 483, 647
Hexadecimal (H) : 16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF
Rated voltage : AC 100 to 240 V
Voltage tolerance range : AC 85 - 264 V
Rated frequency : 50/60 Hz
Allowable momentary power outage time : Operation continues with an instantaneous blackout of 10 ms or less.
Power supply fuse : 250V 1A
Inrush current : Maximum 15 A 5 ms max. / AC 100 V, max 25 A up to 5 ms / AC 200 V
power consumption : Includes 19 W input current (7 mA per point, or 5 mA).
24 VDC service power supply : 400 mA
Input specification :
Number of input points : 6 points
Input connection shape : Terminal block (M3 screw)
Input format : sink
Input signal voltage : DC 24 V ± 10%
Input impedance X000 to X007 : 3.3 kΩ
X010 or later : -
Input signal current X000 to X007 : 7 mA / 24 VDC
X010 or later : -
Input ON sensitivity current X000 to X007 : 4.5 mA or more
X010 or later : -
Input OFF sensitivity current : 1.5 mA or less
Input response time : Approximately 10ms X000 to X017 (up to the basic unit built-in number) has a built-in digital filter and can be changed from 0 to 15 ms in 1 ms unit by D8020. When 0 is specified, X000, X001 is 10 μs, and X002 to X017 are 50 μs. (FX1S - 10M□ corresponds to the range from X000 to X005)
Input signal format : No-voltage contact input NPN open collector transistor
Input circuit insulation : Photocoupler insulation
Input operation display : LED ON when input is ON
Number of output points : 4 points
Output connection shape : Terminal block (M3 screw)
Output type / format : Relay output
External power supply : AC 250 V DC 30 V or less
Maximum load Resistive load : 2A or less / per output 8 A or less / per COM terminal
Inductive load : 80VA
Minimum load : DC 5 V 2 mA (reference value)
Open-circuit leakage current : -
ON voltage : -
Response time OFF → ON : About 10 ms
ON → OFF : About 10 ms
Circuit insulation : Mechanical insulation
Output operation indication : LED lit when relay coil is energized
Built-in high speed counter function
1 phase 1 count input : [C235, C236] Up to 2 points: Up to 60 kHz High speed comparison When using SET / RESET: 30 kHz [C237 to C245] Up to 4 points: Up to 10 kHz High speed comparison When using SET / RESET: 10 kHz Processed by high- The sum of the frequencies to be summed (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency).
1 phase 2 count input : [C246] Maximum 1 point: Up to 60 kHz High speed comparison When using SET / RESET: 30 kHz [C247 to C250] Up to 2 points: Up to 10 kHz High speed comparison When using SET / RESET: 10 kHz Frequency processed by the sequencer with high- (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency).
2 phase 2 count input : [C251] Maximum 1 point: Up to 30 kHz High speed comparison When using SET / RESET: 15 kHz [C252 to C255] Up to 2 points: Up to 5 kHz High speed comparison When using SET / RESET: 5 kHz Frequency processed by the sequencer with high- (2-phase counter adds twice the input frequency), the maximum is 60 kHz. High Speed ??Comparison When using SET / RESET, 30 kHz is the maximum for the sum of the frequencies processed by the sequencer with the high-speed counter and pulse density instruction (2-phase counter adds twice the input frequency).
Ambient temperature : 0 to 55 ° C. ... Operating, -20 to 70 ° C....when saved
Relative humidity : 35 to 85% RH (noncondensing)...at operation
Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (80 minutes in total in total) The criterion is based on IEC 61131-2
Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
Impact resistance : 147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2
Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si
tor with period of 30 to 100 Hz
Withstand voltage : When performing the withstand voltage test, make the voltage between each terminal and the ground terminal of the basic unit as follows. Between the power supply terminal (AC power supply) and the earth terminal: AC 1.5 kV 1 minute DC 24 V service power supply and between the input terminal (24 VDC) and the earth terminal: 500 VAC for 1 min Between the output terminal (relay) and the earth terminal: AC 1.5 kV 1 min
Insulation resistance : When conducting the insulation resistance test, perform the following voltage between each terminal and the ground terminal of the basic unit. Between the power supply terminal (AC power supply) and the earth terminal: 500 VDC DC insulation resistance meter 5 MΩ or more DC 24 V service power supply and between the input terminal (24 VDC) and the earth terminal: 500 V DC 500 MΩ or more with the insulation resistance meter Output terminal (relay) Between: 500 MV DC Insulation resistance meter 5 MΩ or more
ground : Class D grounding (grounding resistance: 100 Ω or less)Grounding should be dedicated ground or common ground.
Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
Use altitude : It Can Not Be Used Under An Environment Pressurized To 2,000 M Or Less Under Atmospheric Pressure. It May Break Down.
Shipping Weight : 2 Kg
Estimated Lead Time : In stock. Usually ships in 7-10 working days.
Manufacturer : Mitsubishi Electric
FX3U-16MR/DS
FX 3 U series FX 3 U - 16 MR / DS
Performance specification
Arithmetic control method : Stored program iterative calculation method (dedicated LSI), interrupt function available
Input / output control method : Batch processing method (when END instruction is executed), I / O refresh command, with pulse catch function
Programming language : Relay symbol method + step ladder method (SFC expressible)
Program memory Maximum memory capacity : 64 thousand step comment, 64000 steps including file register
Internal memory capacity / format : 64000 steps (source information storable Yes Ver. 3.00 or higher) / RAM memory (backed up with built-in lithium battery) Battery life: About 5 years
Memory cassette (option) : [Ver.3.00 or later] . FX3U - FLROM - 1M (2000/4000/8000/16000/32000/64000 steps supported Yes Loader function available, source information can be stored in dedicated area 1300 kbytes) [Ver.2.20] . FX3U - FLO-64L (2000/4000/8000/16000/32000/64000 step supported loader function available) . FX3U - FLROM - 64 (2000/4000/8000/16000/32000/64000 steps supported Yes Loader function not available) . FX3U - FLROM-16 (2000/4000/8000/16000 steps supported Yes No loader function)
Write function during RUN : Yes (program changeable during sequencer RUN)
Protection function : With password protection function (by keyword function)
Real time clock Clock function : Built-in 1980 to 2079 (with leap year correction) 2-digit year / 4-digit switchable, monthly difference ± 45 seconds (25 ° C)
Types of instructions Basic instruction : [Ver 2.30 or later] - Sequence instruction 29 pieces - Step ladder instructions 2 pieces [Ver. 2.30 or less] - Sequence instruction 27 pieces - Two step ladder instructions
Application instruction : 219 species 498 pieces
Arithmetic processing speed Basic instruction : 0.065 μs / Instruction
Application instruction : 0.642 μs to several 100 μs / instruction
Number of input / output points Number of input points : (1) 248 points or less (when adding together) (1) + (2) Total: 256 points or less
Number of output points : (2) 248 points or less (when adding together) (1) + (2) Total: 256 points or less
Number of remote I / O points CC-Link : (3) 256 points or less (224 points or less when using FX2N - 16 CCL - M) * The total of remote I / O of CC - Link, AnyWire Bitty, AnyWireASLINK is 256 or less
AnyWire Bitty : (3) 128 or less * Total remote I / O of CC-Link, AnyWire Bitty, AnyWireASLINK is 256 or less
AnyWireASLINK : (3) 128 or less * Total remote I / O of CC-Link, AnyWire Bitty, AnyWireASLINK is 256 or less
AS-i : (3) 248 or less
Total score : (1) + (2) + (3) Total: 384 points or less (when adding together)
device I / O relay Input relay : X000 to X367 248 points (octal number) When added and used
Output relay : Y000 to Y367 248 points (octal number) When added and used
Auxiliary relay For general use : M 0 ~ M 499 500 points You can change the keeping / nonkeeping setting by parameter.
For keeping : M500 to M1023 524 You can change the keeping / nonkeeping setting with the point parameter.
Keep (battery backup fixed area) : M1024 to M7679 6656 points Battery backup fixed area. Area property change is impossible.
Special purpose : M8000 to M8511 512 points
State Initial state : S 0 ~ S 9 Keep / nonkeep setting can be changed by 10 point parameter.
For general use : S10 to S499 Keep / non-keep setting can be changed by 490 point parameter.
For keeping 1 : S500 to S899 Keep / nonkeep setting can be changed by 400 point parameter.
For Annunciators : S900 - S999 You can change the keeping / nonkeeping setting with 100 point parameters.
For keeping 2 : S1000 to S4095 This is a 3096 point battery backup fixed area. Area property change is impossible.
Timer (on-delay) 100 ms : T0 to T191 192 points (0.1 to 3,276.7 seconds)
100 ms (for subroutines and interrupt routines) : T192 to T199 8 points (0.1 to 3,276.7 seconds)
10 ms : T200 to T245 46 points (0.01 to 327.67 seconds)
1 ms integration type : T246 to T249 4 points (0.001 to 32.767 seconds) Battery backup fixed area. Area property change is impossible.
100 ms Integration type : T250 to T255 6 points (0.1 to 3,276.7 seconds) Battery backup fixed area. Area property change is impossible.
1 ms : T256 to T511 256 points (0.001 to 32.767 seconds)
counter 16 bit up : C0 to C99 100 points (0 to 32,767 counts) You can change the keeping / nonkeeping setting by parameter.
16 bit up (keep) : C100 to C199 100 points (0 to 32,767 counts) Keep / nonkeep setting can be changed by parameter.
32 bit up / down : C200 to C219 20 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts) You can change the keeping / nonkeeping setting by parameter.
32 bit up / down (keep) : C220 to C234 15 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts) You can change the keep / no keep setting by parameter.
High speed counter : [32-bit high-speed up / down (keep)] C235 ~ up 8 points in C255 Usable hardware counter 1 phase: 100kHz, 10 kHz 2 phase: 50 kHz (1 multiplication), 50 kHz (4 multiplication) software counter 1 phase: 40 kHz 2 phases: 40 kHz (1 multiplication), 10 kHz (4 multiplication) There are limitations on the points that can be used and the input frequency depending on the conditions to be used.
Data register (32 bits in pair use) For 16-bit general purpose : D0 ~ D199 The setting of keeping / nonkeeping can be changed by 200 point parameter.
For 16 bit keeping : D200 to D511 312 points It is possible to change the keeping / nonkeeping setting by the parameter.
For 16-bit keep (file register) : D 512 to D 7999 7488 points (It can be set as file register in units of 500 points after D 1000, it is a battery backup fixed area. Area property change is impossible.
16 bit special use : D 8000 to D 8511 512 points
For 16 bit index : V 0 to V 7, Z 0 to Z 7 16 points
Extension register : [16 bits] R 0 to R 32767 32768 points Battery backup fixed area. Area property change is impossible.
Extended file register : [16 bits] ER 0 to ER 32767 32768 Only available when a memory cassette is installed.
Pointer JUMP, for CALL branch : P 0 to P 4095 4096 points (for CJ instruction, CALL instruction, P 63 for END jump)
Input interrupt, input delay interrupt : I00□ ~ I50□ 6 points
Timer interrupt : I6□□ - I 8□□ 3 points
Counter interrupt : I010 to I060 6 points (for HSCS instruction)
nesting : [For master control] N 0 to N 7 8 points (for MC command)
constant Decimal number (K) : 16 bits: -32,768 to + 32,767 32 bits: -2, 147, 483, 648 to +2, 147, 483, 647
Hexadecimal (H) : 16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF
Real number (E) : 32 bits: -1.0 X 2 128 to -1.0 X 2 - 126 , 0, 1.0 X 2 - 126 to 1.0 X 2 128 Decimal point representation and exponential representation are possible
String ("") : It is specified by the character enclosed by "". Up to 32 single-byte characters can be used as an instruction constant
Rated voltage : DC 24V
Voltage tolerance range : DC 16.8 to 28.8 V When the power supply voltage is DC 16.8 to 19.2 V, the number of connectable devices can be reduced.
Rated frequency : -
Allowable momentary power outage time : Operation continues with an instantaneous blackout of 5 ms or less.
Power supply fuse : 250 V 3.15 A
Inrush current : Maximum 35 A less than 0.5 ms / 24 VDC
power consumption : It is the value when maximum is consumed by the I / O extension block added to the 25 W basic unit or the special expansion unit / block.
24 VDC service power supply : -
DC 5 V Internal power supply : 500 mA or less Can not be used externally. This is the power supply capacity to be supplied to the I / O expansion block, special expansion block, special adapter and function expansion board.
Input specification :
Number of input points : 8 points
Input connection shape : Fixed terminal block (M3 screw)
Input format : Sink / source
Input signal voltage : DC 16.8 to 28.8 V
Input impedance X000 to X007 : X000 to X005: 3.9 kΩ X 006, X 007: 3.3 kΩ
X010 or later : -
Input signal current X000 to X007 : X000 ~ X005: 6mA / DC24V X006, X007: 7mA / DC24V
X010 or later : -
Input ON sensitivity current X000 to X007 : X000 to X005: 3.5 mA or more X006, X007: 4.5 mA or more
X010 or later : -
Input OFF sensitivity current : 1.5 mA or less
Input response time : Approximately 10 ms X000 to X017 (up to basic unit built-in number) has a built-in digital filter and can be changed in 0 ms to 60 ms in 1 ms unit according to application instructions or D8020. When set to 0, it becomes the following. X000 to X005: 5 μs X 006, X 007: 50 μs
Input signal format : No-voltage contact input At sink input: NPN open collector transistor Source input: PNP open collector transistor
Input circuit insulation : Photocoupler insulation
Input operation display : LED ON when input is ON
Number of output points : 8 points
Output connection shape : Fixed terminal block (M3 screw)
Output type / format : Relay output
External power supply : DC 30 V or less, AC 240 V or less (CE, UL , AC 250 V or less when not compliant with cUL standard)
Maximum load Resistive load : 2A or less / Total load current per common per output should be as follows. Output 1 point / 1 common: 2A or less Output 4 points / 1 common: 8 A or less Output 8 points / 1 common: 8 A or less
Inductive load : 80VA
Minimum load : DC 5 V 2 mA (reference value)
Open-circuit leakage current : -
ON voltage : -
Response time OFF → ON : About 10 ms
ON → OFF : About 10 ms
Circuit insulation : Mechanical insulation
Output operation indication : When the relay coil is energized LED on the panel is lit
Functional specificationBuilt-in high speed counter function :
1 phase 1 count input : [C235 to C240] Up to 6 points: Up to 100 kHz High Speed ??Comparison When using SET / RESET: 40 kHz High Speed ??Band Comparison When using HSZ: 40 - (Instruction Usage Count) [C244 (OP), C245 (OP)] Maximum 2 Points: 10 kHz High Speed ??Comparison When using SET / RESET: 10 kHz High Speed ??Band Comparison When using HSZ: 40 - (Instruction Used Count) [C241 ~ C245] Up to 3 Points: Up to 40 kHz High Speed ??Comparison When using SET / RESET: 40 kHz High Speed ??Band Comparison When Using HSZ>: 40 - (number of times of instruction use) High speed comparison When using SET / RESET, 80 kHz is the maximum for the sum of the frequencies processed by the sequencer (2 phase 4 quadruple counter is combined with 4 times the input frequency). High-Speed ??Band Comparison When using the HSZ, the frequency obtained by "the number of times of use of 80 kHz - 1.5 X HSZ instruction" is the maximum as the sum of the frequencies processed by the sequencer (2 - phase quadruple counter is 4 times the input frequency).
1 phase 2 count input : [C246, C248 (OP)] Up to 2 points: Up to 100 kHz High Speed ??Comparison When using SET / RESET: 40 kHz High Speed ??Band Comparison When using HSZ: 40 - (Instruction Used Count) [C247 ~ C250] Up to 2 Points: Up to 40 kHz High Speed ??Comparison When using SET / RESET: 40 kHz High Speed ??Band Comparison When using HSZ: 40 - (Instruction Used Count) High Speed ??Comparison Total frequency processed by the sequencer when using SET / RESET (2 phase 4 multiplier counter adds 4 times the input frequency ) Is the maximum at 80 kHz. High-Speed ??Band Comparison When using the HSZ, the frequency obtained by "the number of times of use of 80 kHz - 1.5 X HSZ instruction" is the maximum as the sum of the frequencies processed by the sequencer (2 - phase quadruple counter is 4 times the input frequency).
2 phase 2 count input : [C251, C253] Up to 2 points: Up to 50 kHz (1 multiplication, 4 multiplication) High speed comparison When using SET / RESET (1 multiplication): 40 kHz High speed comparison When using SET / RESET (4 multiplication): 10 kHz High speed band comparison When HSZ is used (1x): 40- (instruction number of uses) fast bandwidth comparing HSZ use (quadruple) :( 40- instruction usage count)
Estimated Lead Time : In stock. Usually ships in 7-10 working days.
Manufacturer : Mitsubishi Electric
FX3U-48MT/DS
FX 3 U Series FX 3 U - 48 MT / DS
Arithmetic control method : Stored program iterative calculation method (dedicated LSI), interrupt function available
Input / output control method : Batch processing method (when END instruction is executed), I / O refresh command, with pulse catch function
Programming language : Relay symbol method + step ladder method (SFC expressible)
Program memory Maximum memory capacity : 64 thousand step comment, 64000 steps including file register
Internal memory capacity / format : 64000 steps (source information storable Yes Ver. 3.00 or higher) / RAM memory (backed up with built-in lithium battery) Battery life: About 5 years
Memory cassette (option) : [Ver.3.00 or later] . FX3U - FLROM - 1M (2000/4000/8000/16000/32000/64000 steps supported Yes Loader function available, source information can be stored in dedicated area 1300 kbytes) [Ver.2.20] . FX3U - FLO-64L (2000/4000/8000/16000/32000/64000 step supported loader function available) . FX3U - FLROM - 64 (2000/4000/8000/16000/32000/64000 steps supported Yes Loader function not available) . FX3U - FLROM-16 (2000/4000/8000/16000 steps supported Yes No loader function)
Write function during RUN : Yes (program changeable during sequencer RUN)
Protection function : With password protection function (by keyword function)
Real time clock Clock function : Built-in 1980 to 2079 (with leap year correction) 2-digit year / 4-digit switchable, monthly difference ± 45 seconds (25 ° C)
Types of instructions Basic instruction : [Ver 2.30 or later] - Sequence instruction 29 pieces - Step ladder instructions 2 pieces [Ver. 2.30 or less] - Sequence instruction 27 pieces - Two step ladder instructions
Application instruction : 219 species 498 pieces
Arithmetic processing speed Basic instruction : 0.065 μs / Instruction
Application instruction : 0.642 μs to several 100 μs / instruction
Number of input / output points Number of input points : (1) 248 points or less (when adding together) (1) + (2) Total: 256 points or less
Number of output points : (2) 248 points or less (when adding together) (1) + (2) Total: 256 points or less
Number of remote I / O points CC-Link : (3) 256 points or less (224 points or less when using FX2N - 16 CCL - M) * The total of remote I / O of CC - Link, AnyWire Bitty, AnyWireASLINK is 256 or less
AnyWire Bitty : (3) 128 or less * Total remote I / O of CC-Link, AnyWire Bitty, AnyWireASLINK is 256 or less
AnyWireASLINK : (3) 128 or less * Total remote I / O of CC-Link, AnyWire Bitty, AnyWireASLINK is 256 or less
AS-i : (3) 248 or less
Total score : (1) + (2) + (3) Total: 384 points or less (when adding together)
device I / O relay Input relay : X000 to X367 248 points (octal number) When added and used
Output relay : Y000 to Y367 248 points (octal number) When added and used
Auxiliary relay For general use : M 0 ~ M 499 500 points You can change the keeping / nonkeeping setting by parameter.
For keeping : M500 to M1023 524 You can change the keeping / nonkeeping setting with the point parameter.
Keep (battery backup fixed area) : M1024 to M7679 6656 points Battery backup fixed area. Area property change is impossible.
Special purpose : M8000 to M8511 512 points
State Initial state : S 0 ~ S 9 Keep / nonkeep setting can be changed by 10 point parameter.
For general use : S10 to S499 Keep / non-keep setting can be changed by 490 point parameter.
For keeping 1 : S500 to S899 Keep / nonkeep setting can be changed by 400 point parameter.
For Annunciators : S900 - S999 You can change the keeping / nonkeeping setting with 100 point parameters.
For keeping 2 : S1000 to S4095 This is a 3096 point battery backup fixed area. Area property change is impossible.
Timer (on-delay) 100 ms : T0 to T191 192 points (0.1 to 3,276.7 seconds)
100 ms (for subroutines and interrupt routines) : T192 to T199 8 points (0.1 to 3,276.7 seconds)
10 ms : T200 to T245 46 points (0.01 to 327.67 seconds)
1 ms integration type : T246 to T249 4 points (0.001 to 32.767 seconds) Battery backup fixed area. Area property change is impossible.
100 ms Integration type : T250 to T255 6 points (0.1 to 3,276.7 seconds) Battery backup fixed area. Area property change is impossible.
1 ms : T256 to T511 256 points (0.001 to 32.767 seconds)
counter 16 bit up : C0 to C99 100 points (0 to 32,767 counts) You can change the keeping / nonkeeping setting by parameter.
16 bit up (keep) : C100 to C199 100 points (0 to 32,767 counts) Keep / nonkeep setting can be changed by parameter.
32 bit up / down : C200 to C219 20 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts) You can change the keeping / nonkeeping setting by parameter.
32 bit up / down (keep) : C220 to C234 15 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts) You can change the keep / no keep setting by parameter.
High speed counter : [32-bit high-speed up / down (keep)] C235 ~ up 8 points in C255 Usable hardware counter 1 phase: 100kHz, 10 kHz 2 phase: 50 kHz (1 multiplication), 50 kHz (4 multiplication) software counter 1 phase: 40 kHz 2 phases: 40 kHz (1 multiplication), 10 kHz (4 multiplication) There are limitations on the points that can be used and the input frequency depending on the conditions to be used.
Data register (32 bits in pair use) For 16-bit general purpose : D0 ~ D199 The setting of keeping / nonkeeping can be changed by 200 point parameter.
For 16 bit keeping : D200 to D511 312 points It is possible to change the keeping / nonkeeping setting by the parameter.
For 16-bit keep (file register) : D 512 to D 7999 7488 points (It can be set as file register in units of 500 points after D 1000, it is a battery backup fixed area. Area property change is impossible.
16 bit special use : D 8000 to D 8511 512 points
For 16 bit index : V 0 to V 7, Z 0 to Z 7 16 points
Extension register : [16 bits] R 0 to R 32767 32768 points Battery backup fixed area. Area property change is impossible.
Extended file register : [16 bits] ER 0 to ER 32767 32768 Only available when a memory cassette is installed.
Pointer JUMP, for CALL branch : P 0 to P 4095 4096 points (for CJ instruction, CALL instruction, P 63 for END jump)
Input interrupt, input delay interrupt : I00□ ~ I50□ 6 points
Timer interrupt : I6□□ - I 8□□ 3 points
Counter interrupt : I010 to I060 6 points (for HSCS instruction)
nesting : [For master control] N 0 to N 7 8 points (for MC command)
constant Decimal number (K) : 16 bits: -32,768 to + 32,767 32 bits: -2, 147, 483, 648 to +2, 147, 483, 647
Hexadecimal (H) : 16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF
Real number (E) : 32 bits: -1.0 X 2 128 to -1.0 X 2 - 126 , 0, 1.0 X 2 - 126 to 1.0 X 2 128 Decimal point representation and exponential representation are possible
String ("") : It is specified by the character enclosed by "". Up to 32 single-byte characters can be used as an instruction constant
Rated voltage : DC 24V
Voltage tolerance range : DC 16.8 to 28.8 V When the power supply voltage is DC 16.8 to 19.2 V, the number of connectable devices can be reduced.
Rated frequency : -
Allowable momentary power outage time : Operation continues with an instantaneous blackout of 5 ms or less.
Power supply fuse : 250 V 5 A
Inrush current : Maximum 35 A less than 0.5 ms / 24 VDC
power consumption : It is the value when maximum is consumed in the I / O expansion block or special expansion unit / block added to the 35 W basic unit.
24 VDC service power supply : -
DC 5 V Internal power supply : 500 mA or less Can not be used externally. This is the power supply capacity to be supplied to the I / O expansion block, special expansion block, special adapter and function expansion board.
Input specification :
Number of input points : 24 points
Input connection shape : Removable terminal block (M3 screw)
Input format : Sink / source
Input signal voltage : DC 16.8 to 28.8 V
Input impedance X000 to X007 : X000 to X005: 3.9 kΩ X 006, X 007: 3.3 kΩ
X010 or later : 4.3 kΩ
Input signal current X000 to X007 : X000 ~ X005: 6mA / DC24V X006, X007: 7mA / DC24V
X010 or later : 5 mA / 24 VDC
Input ON sensitivity current X000 to X007 : X000 to X005: 3.5 mA or more X006, X007: 4.5 mA or more
X010 or later : 3.5 mA or more
Input OFF sensitivity current : 1.5 mA or less
Input response time : Approximately 10 ms X000 to X017 (up to basic unit built-in number) has a built-in digital filter and can be changed in 0 ms to 60 ms in 1 ms unit according to application instructions or D8020. When set to 0, it becomes the following. X000 to X005: 5 μs X 006, X 007: 50 μs X 010 to X 0 17: 200 μs
Input signal format : No-voltage contact input At sink input: NPN open collector transistor Source input: PNP open collector transistor
Input circuit insulation : Photocoupler insulation
Input operation display : LED ON when input is ON
Number of output points : 24 points
Output connection shape : Removable terminal block (M3 screw)
Output type / format : Transistor / sink output
External power supply : DC 5 to 30 V
Maximum load Resistive load : 0.5 A or less / Total load current per common per output should be as follows. Output 1 point / common: 0.5 A or less Output 4 points / common: 0.8 A or less Output 8 points / common: 1.6 A or less
Inductive load : 12 W / DC 24 V
Minimum load : -
Open-circuit leakage current : 0.1 mA or less / DC 30 V
ON voltage : 1.5V or less
Response time OFF → ON : Y000 to Y002: 5 μs or less / 10 mA or more (DC 5 to 24 V) Y003 or later: 0.2 ms or less / 200 mA or more (24 VDC)
ON → OFF : Y000 to Y002: 5 μs or less / 10 mA or more (DC 5 to 24 V) Y003 or later: 0.2 ms or less / 200 mA or more (24 VDC)
Circuit insulation : Photocoupler insulation
Output operation indication : LED on the panel when driving the photo coupler
Built-in high speed counter function :
1 phase 1 count input : [C235 to C240] Up to 6 points: Up to 100 kHz High Speed ??Comparison When using SET / RESET: 40 kHz High Speed ??Band Comparison When using HSZ: 40 - (Instruction Usage Count) [C244 (OP), C245 (OP)] Maximum 2 Points: 10 kHz High Speed ??Comparison When using SET / RESET: 10 kHz High Speed ??Band Comparison When using HSZ: 40 - (Instruction Used Count) [C241 ~ C245] Up to 3 Points: Up to 40 kHz High Speed ??Comparison When using SET / RESET: 40 kHz High Speed ??Band Comparison When Using HSZ : 40 - (number of times of instruction use) High speed comparison When using SET / RESET, 80 kHz is the maximum for the sum of the frequencies processed by the sequencer (2 phase 4 quadruple counter is combined with 4 times the input frequency). High-Speed ??Band Comparison When using the HSZ, the frequency obtained by "the number of times of use of 80 kHz - 1.5 X HSZ instruction" is the maximum as the sum of the frequencies processed by the sequencer (2 - phase quadruple counter is 4 times the input frequency).
1 phase 2 count input : [C246, C248 (OP)] Up to 2 points: Up to 100 kHz High Speed ??Comparison When using SET / RESET: 40 kHz High Speed ??Band Comparison When using HSZ: 40 - (Instruction Used Count) [C247 ~ C250] Up to 2 Points: Up to 40 kHz High Speed ??Comparison When using SET / RESET: 40 kHz High Speed ??Band Comparison When using HSZ: 40 - (Instruction Used Count) High Speed ??Comparison Total frequency processed by the sequencer when using SET / RESET (2 phase 4 multiplier counter adds 4 times the input frequency ) Is the maximum at 80 kHz. High-Speed ??Band Comparison When using the HSZ, the frequency obtained by "the number of times of use of 80 kHz - 1.5 X HSZ instruction" is the maximum as the sum of the frequencies processed by the sequencer (2 - phase quadruple counter is 4 times the input frequency).
2 phase 2 count input : [C251, C253] Up to 2 points: Up to 50 kHz (1 multiplication, 4 multiplication) High speed comparison When using SET / RESET (1 multiplication): 40 kHz High speed comparison When using SET / RESET (4 multiplication): 10 kHz High speed band comparison When HSZ is used (1x): 40- (instruction number of uses) fast bandwidth comparing HSZ use (quadruple) :( 40- instruction usage count)
Estimated Lead Time : In stock. Usually ships in 7-10 working days.
Manufacturer : Mitsubishi Electric
FX3U-80MT/DS
Shipping Weight : 2 Kg
- Estimated Lead Time : 5 - 7 working days.
- Manufacturer : Mitsubishi Electric
- Product No. : FX-20P-CAB0
- Product type : Connection cable for programming unit
- Application : FX-20P-G to FX? PLC
- Length m : 1.5
- Shipping weight : 1.5 Kg
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FX0N-32NT-DP
- Manufacturer : Mitsubishi Electric
Estimated Lead Time : In stock. Usually ships in 7-10 working days.
Manufacturer : Mitsubishi Electric
-
FX 0 N - 40 MR - ES / UL
-
FX 0 N series
-
External dimensions : 150 ? 90 ? 87 mm
-
Weight : 0.75 kg
-
Power requirements : 100 to 240V AC +10% , -15% 50/60 HZ
-
Power consumption : 50VA
-
Service supply : 24V DC 200mA
-
Total I/O capacity : Standard base unit is 40 I/O, can be expanded to 128 I/O with 8 I/O expansion, blocks/40 I/O expansion unit.
-
I/O split : Standard base unit has 24 inputs and 16 outputs
-
Programming : All Mitsubishi FX hand held programmers, also various versions of MEDOC.
-
Mounting facilities : 2 ? 4.5 mm (0.18 inch) dia. integral mounting holes, 35 mm (1.38 inch) DIN rail (DIN standard 46277)
FX 3 G series FX 3 G - 40 MR / ES
Arithmetic control method : Stored program iterative calculation method with interrupt instruction
Input / output control method : Batch processing method (when END instruction is executed), I / O refresh command, with pulse catch function
Programming language : Relay symbol method + step ladder method (SFC expressible)
Maximum memory capacity : 32000 steps
- Estimated Lead Time : 5 - 7 working days.
- Manufacturer : Mitsubishi Electric
- Product No. : FX0N-5EC
- Product type : Cable
- Shipping weight : 1.5 Kg
- Estimated Lead Time : 5 - 7 working days.
- Manufacturer : Mitsubishi Electric
- Product No. : FX0N-65EC
- Product type : Extension cable for extension unit
- Length m : 0.65m
- Shipping weight : 1.5 Kg
- Condition : Brand New
- Warranty : 1 Years
- Product Number : FX0N-8EYR-ES/UL
- Manufacturer :Mitsubishi Electric